background image

© G

ul

dm

an

n GB/US-2583/04/2022 • # 558526_3

© G

ul

dm

an

n GB/US-2583/04/2022 • # 558526_3

9

The emergency lowering must be used in emergencies only. This requires 

qualified assistance. 

You must contact the dealer before using the LP7 & the LP7+ again. Remove 

the key after installation and keep it with the manual.

The electric emergency lowering device is activated by turning the key switch 

to the left for 10 seconds. The lifting platform will then begin its descent. The 

lifting platform will stop if the key is released. If the key is not activated for 10 

seconds, the electrical emergency lowering device will be deactivated, after 

which it can be activated again.

The switch is located in the left tower on the lifting platform.

Description of emergency lowering – access ramp

 

The access ramp is fitted with a 

hexagonal screw on the left side. 

Remove this screw and the access 

ramp can be closed up.

Important!

When the screw is removed from the 

access ramp, the ramp can no longer 

be secured. Hold onto the access 

ramp when removing the screw.

Safety curtain

The safety curtain ensures that nobody can move beneath the lifting platform 

when it is at its high est level and thereby risk getting trapped when the lifting 

platform is lowered. The safety curtain is fitted upon delivery.

If the safety curtain has not been installed, or if it is damaged and the area 

beneath the lifting platform cannot be accessed, the lifting platform cannot be 

used until the problem has been solved.

Summary of Contents for Stepless LP7

Page 1: ...GB US LP7 LP7 Lifting platform User manual vers 3 00 ...

Page 2: ...ng instructions 7 2 03 Safety functions 8 2 04 Accessories 10 3 00 Dismantling and transport 11 4 00 Maintenance and storage 11 4 01 Cleaning 11 4 02 Storage and keeping 11 4 03 How is corrosion avoided 11 4 04 What maintenance is required by the owner 11 5 00 Servicing and useful life 12 5 01 Useful life and servicing 12 5 02 General inspection 12 5 03 Troubleshooting 13 6 00 Technical specificat...

Page 3: ... during use There are also handrails on both sides of the lifting platform The LP7 is fitted with doors as a standard feature The lifting platform is designed and manufactured in relation to applicable norms LP7 can lift up to 800 mm 31 LP7 can lift up to 1500 mm 59 The lifting interval of the LP7 and the LP7 can be adjusted between heights of 50 1500 mm 2 59 The lifting platform may be used in te...

Page 4: ...g platform The lifting platform s secondary power source battery must be disconnected via the key switch when the service engineer is working beneath the lifting platform The MAXIMUM load of 350 kg 770 lbs must not be exceeded The lifting platform and access ramp must be swept clean of gravel fallen leaves snow etc before use The lifting platform is to be used to transport people and must be used ...

Page 5: ...he lifting platform This rule applies even if safety devices are in place 4 Once the lifting platform has been installed connected and can be raised lowered only one person must work at the lifting platform at a time Safety equipment When working beneath the lifting platform a safety stop MUST be used to mechanically block the lifting platform from descending 1 06 Assembly The LP7 LP7 must be asse...

Page 6: ...yyyy mm dd Xxxxxxxx Explanation of labels Manufacturer Manufacturer CE marking This represents the manufacturer s declaration that the product comply with MDR Warning sign General warning IFU Read the manual before starting work REF Part number SN Serial number Emergency lowering label Turn the key to O to turn the lifting platform off Turn the key to I to turn the lifting platform on Turn the key...

Page 7: ...amp is all the way up and 1 is held down the lifting plat form will begin its ascent The lifting platform only ascends when 1 is active ly held down hold to run 4 When the lifting platform is level with the landing the lifting platform stops automatically and the user can drive onto the landing 5 When using the safety gate it is opened automatically It is electronically secured and cannot be opene...

Page 8: ...n the dealer must be contacted before the LP7 LP7 are used again The emergency stop button 3 is located at the top of the right tower It stops all movement when activated Restarting the control system The emergency stop button must be pulled out and the LP7 LP7 can be restarted by pressing the control buttons Alternatively activate the emergency stop button for 5 seconds and then release it to res...

Page 9: ... The switch is located in the left tower on the lifting platform Description of emergency lowering access ramp The access ramp is fitted with a hexagonal screw on the left side Remove this screw and the access ramp can be closed up Important When the screw is removed from the access ramp the ramp can no longer be secured Hold onto the access ramp when removing the screw Safety curtain The safety c...

Page 10: ...e lifting platform will issue a visual alert on the control panel The lifting platform cannot be used in the event of an overload Remove load so that the lifting platform can be operated again 2 04 Accessories Extra operating panel External control panels with UP or DOWN button for wall or free standing installation The control panel is fitted with a lock The control panel is also available in a w...

Page 11: ... pressure they must not be rinsed under high pressure Never use acids bases or solvents for cleaning 4 02 Storage and keeping No special requirements Please note however that the batteries life span is shortened if they are not connected to the charger for a long period of time 4 03 How is corrosion avoided The LP7 LP7 are made of corrosion resistant materials and require no further corrosion prev...

Page 12: ...lifting actuator must be replaced after 10 000 lifts The life span is based on correct usage cleaning and maintenance as well as two annual inspections and maintenance by qualified personnel or the Guldmann Service Team After this period the LP7 LP7 must be assessed by qualified personnel before future use Spare parts lists and drawings can be ordered from the manufacturer or the distributor 5 02 ...

Page 13: ...ly open Check that there are no foreign objects between the door and the lifting platform Run the lifting platform as normal If the problem continues contact the supplier to adjust the door lock The lifting platform does not go down after the upper door has been closed The upper door shows no sign that it has been closed and locked Press the UP button until the door is open Check that there are no...

Page 14: ...s made during the Warranty Period for malfunction or equipment defect Guldmann will repair or replace the equipment at no additional cost to you Guldmann retains sole discretion as to whether the equipment will be repaired or replaced The warranty does not cover any part of the equipment that has been subject to damage or abuse by the user or others The warranty does not cover any part of the equi...

Page 15: ...s Guldmann s Service and Information Console SIC A Guldmann Service Training Certificate and SIC password are valid for three years only USA from the date the technician is first certi fied Thereafter the technician must undergo re certification training to obtain a new valid certificate and password Any parts or components repaired or replaced by a Guldmann Certified Technician will be guaranteed...

Page 16: ...US 2583 04 2022 558526_3 V Guldmann A S Corporate Office Tel 45 8741 3100 E mail info guldmann com www stepless com Guldmann Inc Tel 800 664 8834 Tel 813 880 0619 Fax 813 880 9558 info guldmann net www stepless net ...

Reviews: