17
Two voltage ranges are available on each
universal thermocouple connector for measuring
small voltages:
range -60 mV to +140 mV
range -18 mV to +18 mV
Use
the
white
uncompensated
connector
connected according to the picture.
Terminals
______________________________________
Inputs (0 to 20) mA, (0 to 10) V, binary inputs and the counter are
equipped with a two-part, self-locking WAGO terminal block.
Insert
flat-bladed
screwdriver
to
rectangle terminal hole and push
screwdriver towards away from
you - contact is released. Insert
wire to released terminal (circular
hole behind the rectangular one)
and close the terminal by
removing the screwdriver.
The terminal block can be removed from the device without the need to
disconnect individual wires!
Connection of the binary and counter input: