background image

730385.doc 

Base mounting gasket For Spotlight 

728372 

Safety glass lens 

B-23186 

Relay PC Board 500A  

730511 

Spotlight Reflector 

D-23127  

Gasket For Control Panel 

729962 

 
 

NOTE: 
THE  CONTROL  PANELS  USED  WITH  GUEST  MODELS  501A,  502A,  OR  503A  WILL 

NOT 

OPERATE THE MODEL 500A SPOTLIGHT.  
 
 
 
 
 
 

 

 
 

Troubleshooting 

 

Under normal use, your Guest Beamer spotlight will provide you with many 
years of reliable service. 

If an operational problem occurs: 

Confirm  that  all  fuses  are  intact.  

If a fuse 

has

 blown, do not replace the 

fuse until the   cause of the problem has been located and corrected.  NEVER replace a 
blown fuse with a higher value fuse.  

Most  problems  are  caused  by  poor  wiring  connections. 

Confirm 

that all wiring  connections are accurate

 

and well made. Be sure that the spotlight and 

control  are  connected  to  a    12  volt  DC  power  source  capable  of  supplying  10  amps 
even while other equipment is operating.  (See diagram on page 5.) 

If  the  spotlight  does  not  move  or  light

, remove the 4 bolts that fasten 

the  spotlight  onto  the      mounting  surface  and  gently  lift  the  light  until  you  can  see 
inside

 

its  base  .    Avoid  cutting  any  wires.    Gently  inspect  the  base  for  broken 

connections.  Examine  the  circuit  board  for  loose  plug  connectors,  blackened 
components or corrosion. Replace the circuit board if it appears damaged. If there are 
no loose wires or signs of water penetration, re-install the spotlight and then replace 
the control pad.  

Summary of Contents for 500A BEAMER

Page 1: ...DEL 500A BEAMER REMOTE CONTROL SPOTLIGHT INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...omplete with spotlight and remote control panel This unit is designed for 12 volt operation only Tools and additional materials required Electric drill with 1 2 13mm 5 16 8mm and 3 16 5mm bits Wire cr...

Page 3: ...m the box and use it as a template for the footprint of the light Note Front mounting holes are further apart than rear mounting holes Mark the location of the four corner holes and the center hole sq...

Page 4: ...location for the control panel Be sure you will have access to the area behind the location and that you will be able to drill holes there without damaging existing wiring or structures Do not place t...

Page 5: ...Guest Model 500A Spotlight has two types of wiring connections They are Power supply wires the larger red and black wires that bring 12 volts DC power to the spotlight and to the control panel Contro...

Page 6: ...ccessory panel Install fuse and fuse holders as shown in diagram A 10 amp circuit breaker can be installed instead of an in line 10 amp fuse If the light will be less than 30 feet 9m from its power so...

Page 7: ...ight is accidentally activated during daylight the operator will be more likely to notice and turn the spotlight off before draining a battery Maintenance Under normal conditions mild detergent and wa...

Page 8: ...igher value fuse Most problems are caused by poor wiring connections Confirm that all wiring connections are accurate and well made Be sure that the spotlight and control are connected to a 12 volt DC...

Page 9: ...p but not down or left but not right and the wiring has been checked replace the control panel If your light has a problem that is not described above contact the Guest Company Service Department for...

Page 10: ...is is the exclusive remedy and consequential damages are excluded where permitted by law The Guest Co 95 Research Parkway Meriden CT 06450 USA Tel 203 235 4421 Email info guestco com Fax 203 235 0039...