background image

730385.doc 

results use waterproof telephone splices or solder the wire connections, 

and then cover 

them with heat-shrink tubing. 

 

This spot/flood light requires a source of 12 volt DC power that is capable of supplying 
10 amps of current even when other equipment is operating.  For best results, run two 
new wires from the red   (

+

) positive and black (

) negative power wires of the light 

directly to the main 12 volt DC accessory panel.  Install fuse and fuse holders as shown 
in diagram.  A 10 amp circuit breaker can be installed instead of an in-line 10 amp fuse.  
If the light will be less than 30 feet (9m) from its power source, use 12 gauge (3mm) 
power supply wires. If the distance will be more than 30 feet (9m), use 10 gauge (5mm) 
wires. 

Complete the wiring connections as shown below: 

 
   

 

 

 

Operation

 

Foam Gasket

10-12 ga. Butt Connector

10 Amp Fuse 
(or circuit breaker)

     Black

12 volts DC

Red 
12 volts DC

Weather-proof 

phone wire splice
or soldered connection

18-22 ga. Butt Connector

    Black
12 volts DC

      Red
12 volts DC

2 Amp
 Fuse

“CONTROL” 

white wires

Summary of Contents for 500A BEAMER

Page 1: ...DEL 500A BEAMER REMOTE CONTROL SPOTLIGHT INSTALLATION AND OPERATION INSTRUCTIONS IMPORTANT READ THESE INSTRUCTIONS BEFORE INSTALLING AND USING THIS PRODUCT KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE...

Page 2: ...omplete with spotlight and remote control panel This unit is designed for 12 volt operation only Tools and additional materials required Electric drill with 1 2 13mm 5 16 8mm and 3 16 5mm bits Wire cr...

Page 3: ...m the box and use it as a template for the footprint of the light Note Front mounting holes are further apart than rear mounting holes Mark the location of the four corner holes and the center hole sq...

Page 4: ...location for the control panel Be sure you will have access to the area behind the location and that you will be able to drill holes there without damaging existing wiring or structures Do not place t...

Page 5: ...Guest Model 500A Spotlight has two types of wiring connections They are Power supply wires the larger red and black wires that bring 12 volts DC power to the spotlight and to the control panel Contro...

Page 6: ...ccessory panel Install fuse and fuse holders as shown in diagram A 10 amp circuit breaker can be installed instead of an in line 10 amp fuse If the light will be less than 30 feet 9m from its power so...

Page 7: ...ight is accidentally activated during daylight the operator will be more likely to notice and turn the spotlight off before draining a battery Maintenance Under normal conditions mild detergent and wa...

Page 8: ...igher value fuse Most problems are caused by poor wiring connections Confirm that all wiring connections are accurate and well made Be sure that the spotlight and control are connected to a 12 volt DC...

Page 9: ...p but not down or left but not right and the wiring has been checked replace the control panel If your light has a problem that is not described above contact the Guest Company Service Department for...

Page 10: ...is is the exclusive remedy and consequential damages are excluded where permitted by law The Guest Co 95 Research Parkway Meriden CT 06450 USA Tel 203 235 4421 Email info guestco com Fax 203 235 0039...

Reviews: