F
Compressor gets started too
often
Too much condensate in the air jet
Drain the condensate
Compressor is overloaded
G Safety valve blowing off
Pressure in the air jet exceeds the set
cut-off pressure
Have the pressure switch adjusted/replaced by an
authorised person (Güde service centre)
Safety valve is defective
Replace the safety valve or contact the Güde service
centre
H Compressor getting warm
too much
Air supply is not sufficient
Make sure sufficient air supply and outlet (minimum
distance from wall is 40 cm) is provided
Cooling fins on the cylinder (cylinder
head) are dirty
Clean the cooling fins on the cylinder (cylinder head)
Too long time of appliance operation
Switch the compressor off
I
Compressor being
overheated and keeps
switching off
Compressor is overloaded
Contact the Güde service centre
Compressor is defective
Contact the Güde service centre
Compressor under undervoltage
Contact the Güde service centre
Outdoor temperature of 35°C
Contact the Güde service centre
Servicing table
Servicing intervals apply to standard operating conditions. Intervals are adequately shortened for extreme
operating conditions.
Steps
Intervals
Date
Date
Date
Date
Suction filter check
•
Cleaning
•
Replacement
Weekly
Every 50 hours of operation
At least once a year
Check valve and insert cleaning
Annually
Condensate draining from the air jet
Whenever the appliance was used
Condensate draining from the filter pressure
control valve
Whenever the appliance was used
Filter insert cleaning
As needed
Compressor cleaning
As needed
Screwing check
After 10 hours of operation for
the first time
Then every 500 hours of
operation