Failure removal
Error
Causes
Remedy
Gas odour
Gas hose or leaking connection.
Stop the gas supply to the device.
Move out of the danger zone immediately
and make sure that no other persons are in
the danger zone.
Call the fire brigade.
The motor does not start
No electricity
Check the cable, connect it to the power
supply and if necessary replace it or have it
repaired by an expert.
Piezo-ignition does not
ignite
Electrode in incorrect position
Call specialist
No gas
Gas cylinder empty
Replace gas cylinder
Closed valve on the gas cylinder
Open valve
Burner ignites, flame goes
off as soon as the gas valve
is turned on
Thermal element not yet hot properly Try again
Safty thermostat turned off
Let the device cool down and then retry.
Burner flame goes off
during operation
Excessive gas output
Have the reduction valve checked or replaced
Gas cylinder empty
Replace gas cylinder
Insufficient gas input
Check and clean motor grid
Check fan
Wind or air draught extinguishes
flame
Place the device outside wind or air draught,
let it cool down for several minutes and then
retry.