DIRECTIONS FOR USE 

CLEANING 

•  Always unplug the unit before servicing in any way.

GENERAL CLEANING

•  Inside the base of the unit. 

Pour excess water out of the unit. Wash out the unit with fresh  

  water using the cleaning brush and a soft cloth as needed. 

Do not submerse the base of the  

  unit into water, or allow water to enter inside the dry air exhaust port of the unit.
•  Water tank. 

Empty water tank. Pull and remove mist spout out of the tank. Also remove the  

  mist diffuser located under the spout. Clean the mist tube with fresh water and a light brush  

  (bottle cleaning brush is recommended). Return mist diffuser and spout after cleaning.   

•  Outer surface of the unit. 

Wipe the surface of the unit with a soft, damp cloth if needed. If 

  you notice an accumulation of water during usage, reduce humidity and dry outer surface with 

  a cloth. 

DESCALING

•  Depending on usage and water type, cleaning to remove scale may be required 

  weekly or every other week to optimize unit performance. 
•  If you live in a hardwater area, we recommend the use of distilled water for your    

  humidifier. This will help reduce the precipitation of minerals or ‘white dust’.
•  Do not clean the unit or water tank with detergents or cleaning chemicals of any kind.

CLEANING

4. Adjustable Humidistat

  Set the desired humidity in % by pressing the Adjustable Humidistat button. We recommend a 

  relative humidity of between 40% and 50%. The appliance can be regulated from 40% to 75% 

  in 5% increments. If the humidity exceeds the desired setting, the appliance will turn itself off. 

  The appliance will not turn itself off if it has been set for Continuous Operation (“CO”). The 

  desired value is shown while you are making the selection. After a few seconds, the display 

  automatically switches to the current value. Note: If the room humidity is below 15% then the  

  display will flash.

6. Low/No Water

  When it is time to refill, the low water indicator will blink on the display.

5. Timer

  Press the Timer button to determine the operating time, it can be regulated between 1 and 12 

  hours or for continuous operation.

“Timer” LED is displayed when in use.

7. Auto Shut Off

  The unit will automatically shut off when the water level is too low. If this happens, unplug the  

  unit, remove the tank and refill.

3. Auto Humidistat

  Press the Auto button to activate the automatic humidity function, then the ideal humidity of 

  50% is maintained. When the humidity level in the room is less than the auto humidity level  

  (50%), the humidifier will continue to produce moisture automatically. Once the room level is  

  met, the humidifier will turn itself off. 

“Auto” LED is displayed when in use.

®

Mist Spout

Tank

Control Panel

Power 

Plug

Base

Mist Diffuser

Mist Tube

Summary of Contents for H1250

Page 1: ...t a en l nea en www guardiantechnologies com Consideramos que el proceso de registro es importante para garantizar el servicio superior a nuestros clientes sin embargo el env o del comprobante de regi...

Page 2: ...of time Unplug the cord when unit is not in use for an extended period of time and or when no one is home Do not keep water in the tank when not in use for an extended period of time READ AND SAVE THE...

Page 3: ...volume or amount of mist that is produced by the unit can be adjusted to three levels based on need TIMER Preset the humidifier to automatically turn off in 1 to 12 hours ADJUSTABLE HUMIDISTAT Preset...

Page 4: ...he humidifier on a water resistant surface as water can damage furniture and some flooring Do not place unit directly on carpet towels blankets or other absorbent surfaces Guardian Technologies will n...

Page 5: ...Adjustable Humidistat Set the desired humidity in by pressing the Adjustable Humidistat button We recommend a relative humidity of between 40 and 50 The appliance can be regulated from 40 to 75 in 5...

Page 6: ...n of humidity Lower mist control setting Unit not level and water is accumulating Unplug and place on level surface Point spray away from objects Raise unit on a water resistant level surface 2 3 feet...

Page 7: ...from state to state in the U S A The product warranty registration can be completed online at www guardiantechnologies com We consider the registration process important to ensuring superior service t...

Page 8: ...dessous peut provoquer une d charge lectrique ou des blessures graves LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENTS Le non respect des avertissements mentionn s ci dessous peut provoquer une d c...

Page 9: ...tomatique de l humidificateur entre 1 et 12 heures HUMIDOSTAT R GLABLE Permet de r gler l humidificateur pour atteindre le taux d humidit souhait HUMIDOSTAT AUTOMATIQUE Contr le l humidit de la pi ce...

Page 10: ...ction Utilisation des boutons de commande pour d couvrir les fonctionsdisponibles Remarque lorsque vous mettez en marche l appareil l humidostat affiche un taux d humidit entre 15 et 90 Si le taux d h...

Page 11: ...umidostat r glable R glez le taux d humidit souhait en appuyant sur le bouton de l humidostat r glable Nous recommandons une humidit relative entre 40 et 50 L appareil peut tre r gl entre 40 et 75 par...

Page 12: ...t mise Trop d eau retirez un peu d eau du r servoir Le taux d humidit d sir est inf rieur au taux d humidit de la pi ce V rifier le r glage de l humidostat Le r servoir contient peut tre des r sidus d...

Page 13: ...ir cette garantie en accord avec les conditions susmentionn es Pour faire valoir la pr sente garantie l appareil complet doit tre envoy en port pay Guardian Technologies LLC Veuillez fournir des infor...

Page 14: ...el ctrico o lesiones severas LEA Y GUARDE ESTAS INSTRUCCIONES ADVERTENCIAS El no cumplir las advertencias que se enumeran a continuaci n puede provocar un choque el ctrico o lesiones severas Desconect...

Page 15: ...se apague despu s de 1 a 12 horas HIGROSTATO AJUSTABLE Programe el humidificador con anterioridad para que alcance el nivel de humedad deseado HIGROSTATO AUTOM TICO Controla la humedad de la habitaci...

Page 16: ...s cobijas u otras superficies absorbentes Guardian Technologies no se har responsable por da os ocasionados por derrames de agua RELLENO Aseg rese que la unidad est desconectada INSTRUCCIONES DE USO 3...

Page 17: ...endo el bot n del higrostato ajustable Recomendamos que la humedad relativa est entre 40 y 50 Puede regularse el aparato desde 40 hasta 75 en incrementos de 5 Si la humedad supera el ajuste deseado el...

Page 18: ...produce vapor Cantidad excesiva de agua Saque algo de agua del dep sito La humedad deseada es menor que la humedad actual en la habitaci n Controlar los ajustes del higrostato Pudiera haber residuos...

Reviews: