G
uar
di
an
F
al
l P
ro
te
ct
io
n
63
05
S
. 2
31
st
St
.,
Ken
t,
W
A
9
80
32
6
Compress
tensioner
handle
4. Install compatible anchorage connector at first HLL span termination point. Then, connect anchor (live) end
of Big Boss HLL to anchorage connector with a carabiner. Repeat at second HLL span termination point by
connecting Big Boss HLL tensioner to second compatible anchorage connector.
5. Pull initial rope slack through tensioner by hand. This step is only to remove excess rope slack, not to
achieve proper tension.
6. Compress and hold tensioner handle and rotate handle until correct tension is reached. Apply force to
handle in turning direction only, as shown by arrow on handle.
7. To confirm proper tension, locate midpoint of HLL span. At this point, rope sag must match data specified in
graph and table on pg. 7. Never exceed specified sag. Sag less than specified is acceptable, but be sure to
never over-tension rope. Always use sag method to ensure system is set correctly. Rope will slip to prevent
over-tensioning, however it is not necessary to tension to this point. Never extend handle in any way to
increase leverage.
Rotate handle
as shown
Summary of Contents for Big Boss HLL