Guardian AC5109 Use & Care Instructions Manual Download Page 5

Note: Do NOT stick any foreign objects or your fingers inside the unit.

Caution: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the

unit while cleaning as they will damage the products.

NEVER use alcohol or other solvents.

What is CADR?

CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by

an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing

fine particles from things like tobacco smoke and plant pollens from the room.

Clean Air Delivery Rate

From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. 

Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster

the unit filters the air.

Refer to website for individual model CADR numbers.

TROUBLESHOOTING GUIDE

Check that the unit is plugged into a working electrical outlet.

Check to see if the motor protector is triggered.

Check that the filter and back panel are installed correctly.

Unplug/replug into the outlet.

Call customer service.

PROBLEM

Unit shuts off unexpectedly

or does not operate.

SOLUTION

No air circulating from the unit.  Unplug unit.  Check filter.  Clean or replace filter if necessary.
Odors not removed.

Make sure the filter is clean.  Replace if necessary.

Discharged air has an odor.

Check to see if the filter is heavily soiled. Replace if necessary.

Turn off the ionizer.  

E-8

E-9

Increase in noise level.

Make sure the filter is clean.  Replace if necessary.

Filter indicator light on display

is flashing. 

Replace filter and reset light.

UV-C indicator light on display

is flashing. 

Replace bulb and reset light.  

UV-C Bulb Replacement Indicator: 

The UV light on the display will flash blue when it is time to replace the UV bulb.

1. Remove the filter from the unit.

2. After removing the filter, use a Philips head 

   screwdriver to remove 4 screws and detach 

   the UV-C bulb cover.
3. The UV-C bulb is removed by carefully 

    grasping the bulb with a clean cloth or tissue

    and twisting the bulb ¼ turn. Remove from unit.
4. The UV-C bulb is reinstalled by reversing

    the process in Step 3.
5. Replace the UV-C cover and re-attach

    with 4 screws.
6. Return filter and back panel before operating unit.
7. Reset the UV light by holding the "UV" button

    down for 5 seconds.

IMPORTANT: The UV-C bulb should be replaced every 10 months depending on use.

Visit our website www.guardiantechnologies.com to purchase a replacement bulb.

CLEANING & MAINTENANCE

CLEANING

• Always unplug the appliance before you clean it.

• Never immerse the appliance in water or any other liquid.

• Never use aggressive or flammable cleaning agents such as bleach or alcohol to clean any

  part of the appliance.

UV-C LIGHT REPLACEMENT

Air quality status remains poor.    Check to see if the filter is heavily soiled. Replace if necessary.

Increase the fan speed to circulate air.

BODY OF THE APPLIANCE

Regularly clean the inside and outside of the body to prevent dust from collecting.

1. Wipe away dust with a soft dry cloth from the body of the appliance.

2. Clean the air inlet and the air outlet with a soft dry cloth.

PRE-FILTER SCREEN

The pre-filter/charcoal layer collects larger dust and debris and should be cleaned monthly or

more frequently depending on use. Remove and clean regularly with the brush attachment of

your vacuum cleaner. This will remove the lint and dirt and help maintain the life of the filter.

(See filter replacement to locate and clean or remove the filter).

Replacement pre-filters are available by visiting our website at www.guardiantechnologies.com. 

REPLACEMENT PARTS

FILTER:         
Model No.

FLT5100

O

Replacement Bulb

Model No. LB5100

Carbon Replacement 4-PACK

Model No. FLT51CB4

Check out our

Filter Replacement Program

www.guardiantechnologies.com

IMPORTANT: To maintain performance of the air

cleaner, use Guardian Technologies GENUINE

Replacement Parts only. To purchase visit our 

website www.guardiantechnologies.com. 

Summary of Contents for AC5109

Page 1: ...at are the result of normal wear and tear will not be considered manufacturing defects under this warranty If this product should become defective within the warranty period we will repair or replace any defective parts free of charge All warranty repairs must be completed by Guardian Technologies LLC This warranty gives you specific legal rights and you may also have other rights other rights may...

Page 2: ...gent or similarly qualified persons in order to avoid a hazard Use appliance only for intended household use as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons WARNING Cancer and Reproductive Harm For more information go to www P65Warnings ca gov The 8 hour TWA Ozone for this product is 0 001 ppmv when tested in a 30 m3 ...

Page 3: ...el IMPORTANT The air purifier is shipped with the filter stored in the filter compartment The filter is shipped in a bag to prevent degradation Before using remove and discard bag Display Panel UV AQI A 2h 4h 6h 8h FILTER RESET IONIZER UV C MODE SLEEP LOCK TIMER SPEED AUTO ON OFF UV Back of Unit Air Quality Monitor Sensor HEPA Filter with Charcoal Filter Layer UV C Bulb Cover Compartment under HEP...

Page 4: ...er Reset Indicator flashes to indicate it is time to change the filter Replace the filter according to the instructions pg 7 Press and hold Filter Reset control for approximately 5 seconds the unit will beep before flashing indicator stops AIR QUALITY MONITOR Air Quality Monitor senses and detects the amount of particulate matter PM2 5 in the air The light circle around the display will change col...

Page 5: ...ver to remove 4 screws and detach the UV C bulb cover 3 The UV C bulb is removed by carefully grasping the bulb with a clean cloth or tissue and twisting the bulb turn Remove from unit 4 The UV C bulb is reinstalled by reversing the process in Step 3 5 Replace the UV C cover and re attach with 4 screws 6 Return filter and back panel before operating unit 7 Reset the UV light by holding the UV butt...

Page 6: ...ilisation commerciale abusive ou déraisonnable ou de dommages additionnels Cette garantie ne couvre pas les dommages causés par des réparations non autorisées ou de toute utilisation non conforme avec le manuel des instructions Les défaillances découlant d une usure normale ne seront pas considérées des défauts de fabrication selon la présente garantie Si cet appareil s avère défectueux pendant la...

Page 7: ... un liquide quelconque N utilisez pas cet appareil à proximité de l eau Il faut faire preuve d une extrême prudence lors de l utilisation d un appareil par les enfants ou des personnes handicapées ou à proximité de ces derniers et lorsqu on laisse l appareil en fonctionnement sans surveillance Cet appareil n est pas prévu pour être utilisé par des personnes y compris des enfants ayant des capacité...

Page 8: ...é dans le compartiment à filtre Le filtre est expédié dans un sac pour éviter sa dégradation Avant l utilisation enlevez et jetez le sac Panneau de l écran UV AQI A 2h 4h 6h 8h BOUTON DE RÉINITIALISATION DU FILTRE RESET IONISEUR MODE UV C VEILLE VERROUILLÉ MINUTERIE VITESSE AUTO MARCHE ARRÊT UV Arrière de l appareil Capteur de moniteur de la qualité de l air Filtre HEPA avec couche filtrante au ch...

Page 9: ...r s allumera à l écran Appuyez à nouveau pour l arrêter FILTER RESET 8 Le voyant de réinitialisation du filtre clignote pour indiquer qu il est temps de changer le filtre Remplacez le filtre selon les instructions page 7 Maintenez le bouton de commande de Réinitialisation du filtre enfoncé pendant 5 secondes environ l appareil émettra un bip avant puis l indicateur s arrêtera de clignoter MONITEUR...

Page 10: ...t réinitialisez le voyant L indicateur lumineux UV C clignote sur l écran Remplacez l ampoule et réinitialisez le voyant Voyant de remplacement de l ampoule UV C Le voyant UV situé sur l écran clignotera en bleu lorsqu il est temps de remplacer l ampoule UV 1 Retirez le filtre de l appareil 3 Pour retirer l ampoule UV C saisissez la avec précaution en utilisant un chiffon ou un mouchoir en papier ...

Page 11: ...que se deriven del desgaste inusual el uso comercial abusivo irrazonable o daños suplementarios Esta garantía no cubre los daños que se deriven de reparaciones no autorizadas o de algún uso que no esté de acuerdo con este manual de instrucciones Los defectos que se deriven del uso y desgaste normales no se considerarán defectos de fábrica bajo esta garantía Si durante el período de garantía se det...

Page 12: ...ov No se debe utilizar en exteriores NUNCAbloquee las aberturas para el aire las rejillas salidas del aparato ni coloque el producto sobre una superficie suave como una cama o sofá ya que esto podría provocar que el aparato se vuelque se bloquee la abertura de entrada o la salida del aire No intente reparar o ajustar un funcionamiento eléctrico o mecánico incorrecto de esta unidad El hacerlo anula...

Page 13: ...rtimiento del filtro El filtro se envía en una bolsa para evitar que se degrade Antes de usarlo retire la bolsa y deséchela Panel de la pantalla UV AQI A 2h 4h 6h 8h REAJUSTE DEL FILTRO IONIZADOR MODO UV C SUSPENDER BLOQUEAR TEMPORIZADOR VELOCIDAD AUTOMÁTICO ENCENDIDO APAGADO UV Parte posterior de la unidad Sensor del monitor de calidad del aire Filtro HEPA con capa de filtro de carbón Cubierta co...

Page 14: ... y enciéndala El Indicador de reajuste del filtro parpadea para indicar que es momento de cambiar el filtro Dependiendo del uso del aparato y de las condiciones ambientales el filtro puede durar 6 meses aproximadamente Los pliegues interiores del filtro cambiarán de blanco a color gris cuando esté sucio y haga falta reemplazarlo Es importante mantener y cambiar el filtro para seguir optimizando el...

Page 15: ...Reemplácelo si fuera necesario La luz del indicador filtro está parpadeando Reemplace el filtro y restablezca el sistema La luz del indicador UV C está parpadeando Reemplace el foco y restablezca el sistema Indicador de reemplazo del foco UV C La luz de modo UV en la pantalla parpadeará de color azul cuando sea el momento de reemplazar el foco UV 1 Saque el filtro de la unidad 2 Después de retirar...

Reviews: