OUTDOOR DUAL TECHNOLOGY DETECTOR

INSTALLATION AND USE MANUAL

G-OP-WPIR-W and U is a curtain detector for protection of doors and windows.

This device has double technology detection: it integrates two infrared passive modules and a 

pulsed microwave module, designed to obtain a very narrow detection beam.

The alarm is generated only when both technologies detect at the same time, avoiding false 

alarms.

The device is provided with automatic temperature compensation of its partameters. 

Its dimensions – particularly reduced in height and width – allow an easy installation in the 

narrow spaces available on doors and windows.

The sensor is protected from removal risk, thanks to an integrated anti-removal system.

READ CAREFULLY THIS MANUAL BEFORE INSTALL YOUR NEW ALARM 

SYSTEM. KEEP THIS MANUAL FOR FUTURE REFERENCE.
ONLY QUALIFIED TECHNICIAN MUST INSTALL THIS DEVICE.

INSTALLER MUST FOLLOW CURRENT REGULATIONS.
THE MANUFACTURER SHALL NOT BE LIABLE FOR ANY IMPROPER USE OF 

THE PRODUCT, INCORRECT INSTALLATION OR FAILURE TO COMPLY WITH 

INSTRUCTIONS OF THIS MANUAL AND THE LAW REGARDING ELECTRICAL 

SYSTEMS.

A

TECHNICAL

DETECTION AREA

BATTERY DURATION (ESTIMATED) IS PROPORTIONAL TO:

 

HEAT CYCLES OF THE BATTERY WHICH AFFECT CHARGE CAPACITY AND DURATION

 

WORKING TEMPERATURE OF THE BATTERY (E.G.: AT TEMPERATURE LOWER THAN 0°C THE BATTERY DURATION MAY DECREASE OF 50 %)

 

NUMBER OF DETECTIONS TO WHICH THE SENSOR IS SUBJECT: IF THE SENSOR IS INSTALLED IN HIGH FREQUENCY OF PASSAGE, THE BATTERY DURATION WILL DECREASE DRAMATICALLY

THE MAX RANGE DEPENDS SIGNIFICANTLY ON ENVIRONMENT TEMPERATURE.

Power supply

8 ÷ 14 V

DC

n. 1 lithium battery pack, 6 V

Absorption 

*

Stand-by: about 8 mA

Stand-by: about 25 µA

Alarm: about 5 mA

Autonomy (estimated) 

**

-

About 2 years

Stabilization Time (at power-up)

About 120 seconds

About 120 seconds

Quiet Time between detections 

***

-

About 30 seconds

TEST mode lasting

-

5 minutes (at the end, the sensor backs to 

NORMAL mode even if J.MODE = CLOSED)

Detection technologies

Infrared (double head) + Pulsed microwave

Infrared (double head) + Pulsed microwave

Microwave frequency / working mode

24 GHz / Pulsed

24 GHz / Pulsed

Detection Area (H x W x D) 

*

Door: 3 x 2,5 x 0,3 m

Window: 1,2 x 0,8 x 0,2 m

Door: 3 x 2,5 x 0,3 m

Window: 1,2 x 0,8 x 0,2 m

Radio working frequency

-

-

Radio range

-

-

Radio signalling

-

-

Wired outputs

OptoMOS, N.C. type

Max 60V /100mA / 16Ω

Insulation: 1500V

Alarm

Tamper

OptoMOS, N.C. type

Max 60V / 75mA / 10Ω

Insulation: 1500V

Alarm

Tamper

Low Battery

LED signalling

2 red LED (IR heads detection)

1 green LED (microwave detection)

1 blue LED for alarm

2 red LED (IR heads detection)

1 green LED (microwave detection)

1 blue LED for alarm

Temperature 

****

 / Humidity

-40 ÷ +70 °C / 95 %

-40 ÷ +70 °C / 95 %

Case

ABS antiUV

ABS antiUV

Dimension (H x W x D)

40 x 330 x 30 mm

40 x 330 x 30 mm

Internal space for transmitter (H x W x D)

-

20 x 70 x 30 mm

*

 All the data are approximate, for sensor in NORMAL mode at operating temperature of 21 °C

**

 Mean value for 50 detections-alarms/day + supervision

***

 Sensor working in NORMAL mode

****

 Automatic parameters adjustment with temperature, linear compensation

1

2

DIP2 = ON

DIP2 = OFF

ver.: 2019-06-11_1_fr

G-OP-WPIR-W and -U

G-OP-WPIR-W (wired)

G-OP-WPIR-U (Universal)

WINDOW frame 

installa�on

DOOR frame 

installa�on

Summary of Contents for G-OP-WPIR-W

Page 1: ...DETECTIONS TO WHICH THE SENSOR IS SUBJECT IF THE SENSOR IS INSTALLED IN HIGH FREQUENCY OF PASSAGE THE BATTERY DURATION WILL DECREASE DRAMATICALLY THE MAX RANGE DEPENDS SIGNIFICANTLY ON ENVIRONMENT TEMPERATURE Power supply 8 14 VDC n 1 lithium battery pack 6 V Absorption Stand by about 8 mA Stand by about 25 µA Alarm about 5 mA Autonomy estimated About 2 years Stabilization Time at power up About 1...

Page 2: ... caused by presence of regular mosquito nets or rollers within the detection area provided that nets are always taut and rollers are fully raised or lowered If these indications are not met increase both the risk of false alarms and the battery consumption for G OP WPIR U clothes hung etc This avoid unwanted detections During adjustment perform as detection tests as necessary to obtain a correct s...

Page 3: ...minutes even without opening the J MODE jumper The automatic exit is also signalled by the sequential turning on of the LEDs If necessary to increase the TEST mode time simply open and close the J MODE jumper The TEST mode is set as default NORMAL mode J MODE OPENED It s the mode the detector MUST be set when in normal working In this mode after last detection and alarm transmission the detector w...

Page 4: ...on period takes about 2 minutes the infrared and microwave LEDa light on in case of detection At the end of the stabilization time the sensor is ready for use BATTERY ONLY G OP WPIR U Caution the device works by lithium battery Replace the battery exclusively with one of the same type Follow the polarity indicated in the instructions Dispose of empty batteries following the current regulations eve...

Reviews: