IP 20
8m
max 6 m
min 2 m
AC
220-240 V
50-60 Hz
max
2000 W
PC
106g
CONNECTION-WIRE DIAGRAM:
The wires come in and out from the bottom
The wires come in and out from the side
TEST:
• Turn the TIME knob anti-clockwise on the minimum (10s). Turn the
SENS knob clockwise on the maximum (+). Turn the LUX knob cloc-
kwise on the maximum (sun).
• When you switch on the power, the light will be on at once. And
10sec±3sec later the light will be off automatically. Then if the sen-
sor receives induction signal again, it can work normally.
• When the sensor receives the second induction signals within the
first induction, it will restart to time from the moment.
• Turn LUX knob anti-clockwise on the minimum (3). If the ambient li-
ght is less than 3LUX (darkness), the inductor load could work when
it receives induction signal.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise the sensor lamp could not work!
NOTES:
• Electrician or experienced human can install it.
• Can not be installed on the uneven and shaky surface
• In front of the sensor there shouldn’t be obstructive object affecting detection.
• Avoid installing it near the metal and glass which may affect the sensor.
• For your safety, please don’t open the case if you find hitch after installation.
• In order to avoid the unexpected damage of product, please add a safe device of current 6A when installing microwave
sensor, for example, fuse, safe tube etc.
SOME PROBLEM AND SOLVED WAY:
• The load don’t work:
a. Check the power and the load.
b. Whether the indicator light is turned on after sensing? If yes, please check load.
c. If the indicator light is not on after sensing, please check if the working light corresponds to the ambient light.
d. Please check if the working voltage corresponds to the power source.
• The sensitivity is poor:
a. Please check if in front of the sensor there shouldn’t be obstructive object that affect to receive the signals.
b. Please check if the signal source is in the detection fields.
c. Please check the installation height.
• The sensor can’t shut automatically the load:
a. If there are continual signals in the detection fields.
b. If the time delay is set to the longest.
c. If the power corresponds to the instruction.