8
TECHNICAL SPECIFICATIONS
for the GTO/PRO SW-5000 & SW-6000 AC Swing Gate Operators
Motor
•GTO/PRO SW-5000
: 1
/
2
hp GTO-Leeson 1625 rpm TEFC; C-Face connection; 115 V, single phase.
•GTO/PRO SW-6000: 1 hp GTO-Leeson 1600 rpm TEFC; C-Face connection; 115 V, single phase.
Gear Reducer
•Totally enclosed 900:1, double reduction gear reducer, with vertical motor flange.
•Machine cut bronze gears run in an oil bath.
•Oil temperature range: –22
°
F to 806
°
F (–30
°
C to 430
°
C).
Power
•GTO/PRO SW-5000: 115 Vac, 60 Hz, 5 A; GTO/PRO SW-6000: 115 Vac, 60 Hz, 9.8 A.
•Requires copper conductors.
•Must be installed by an electrician in accordance to NEC (National Electric Code) and local codes.
•Product relies on a 15 A main disconnect circuit breaker (supplied by the installer).
•One 115 Vac dual GFCI outlet (located below control box) for additional accessories.
Control
•Adjustable auto-close timer: 1 – 120 seconds.
•Independent obstruction settings for opening and closing cycles.
•Diagnostic and error condition LEDs.
•Potentiometers and DIP switches for easy adjustments.
•Six separate terminals for N/O contacts (e.g., safety edges or photoelectric beams).
•Mechanical limit controls.
•GTO remote mounted RF receiver tuned to 318 MHz (other receivers can be accommodated).
Construction
•Zinc plated steel parts for maximum corrosion resistance.
•Mounting brackets can be welded or bolted.
•Lockable foot pedal release (patented) allows manual operation of gate.
Operational Capacity
•Operator compatible with all types of horizontal swing gates / with a maximum opening of 90 degrees
•GTO/PRO SW-5000: maximum weight 1000 lb.; maximum length 20 ft.
•GTO/PRO SW-6000: maximum weight 1800 lb.; maximum length 20 ft.
•Duty Cycle: Continuous.
Dimensions
•Housing: Width 24 in.; Depth 25.5 in.; Height 29.5 in.
•Control Box: Width 14 in.; Depth 6 in.; Height 16 in.
•Shipping Weight: GTO/PRO SW-5000 270 lb.; GTO/PRO SW-6000 276 lb.