The aqua stat powers the inducer draft blower to maintain the desired water temperature. The aqua stat is set at 160°F at
the factory, which means the inducer fan will run until the water in the jacket reaches 160°F. As the outside air
temperatures drops the settings can be raised to a high of 180°F. The aqua stat is set lower at the factory because it is not
necessary to have a high temperature in the fall and spring. Which is when most stoves are installed. By doing this the
stand by heat loss is reduced.
*Only qualified personal should be adjusting the temperature controls.
The on and off switch is to shut the power off to the inducer blower when the firebox is being filled. The outside light is
wired so it can be turned on and off at a remote location.
CONTROL PANEL
AQUA STAT
Controls the
water
temperature
inside the
water jacket.
Factory set at
160°F with a
10° differential.
REOSTAT
This controls the
inducer blowers
speed which
injects air under
the grates.
FAN/LIGHT SWITCH
Controls both
blower and light.
Ensure switch is in
the light position
before opening
fuel door. This
shuts the fan off
and turns on light.
Always put the
switch in the fan
position after
refueling.
23
Summary of Contents for Crown Royal Stoves Multi-Pass 7200MP
Page 2: ......
Page 4: ......
Page 6: ...6 ...
Page 8: ...8 ...
Page 11: ...FURNACE FLOOR PLAN Model 7200MP Model 7300MP 11 ...
Page 12: ...FURNACE FLOOR PLAN Model 7400MP Model 7500MP 12 ...
Page 22: ...22 ...
Page 30: ...30 ...
Page 31: ...ELECTRICAL WIRING DIAGRAM 7200MP 7300MP 7400MP 31 ...
Page 32: ...ELECTRICAL WIRING DIAGRAM 7500MP 32 ...
Page 38: ...38 ...
Page 42: ...Model 7500MP 42 ...
Page 51: ...51 ...
Page 52: ...OWNER S MANUAL ...