Protocol setting: press ON/OFF to choose mode and enter in protocol setting. Codes are
shown in “LOAD” icon, press FUNC to change protocol.
First code: 0-Modbus (for setup communication via RS232 with setting software MTR),
1-SNT (for setup communication with monitoring software UPSilon and SMNP card)
“CC”-current protocol.
INPUT
OUTPUT
LOAD
CONVERTER
BYPASS
Protocol
Current
setting
Factory setting: “1cc”
8)
Press ON/OFF to choose protocol and display current setting.
VAC
INPUT
OUTPUT
LOAD
MODE
CONVERTER
BYPASS
Hz
Current voltage
Current frequency
Current mode
Current protocol
9)
Press ON/OFF to save current setting and exit. If want to change, press FUNC and repeat
the procedures above.
10)
If you want to exit from setting mode and give up saving, press ON/OFF and FUNC
together for 2.5 seconds when in setting mode.
11)
Restart and check if the setting is right.