Datum
Name
gez.
Benennung
Zeich.-Nr.
Blatt
geä.
geä.
geä.
geä.
10
9
8
7
6
5
4
3
2
1
6
Terminal X7
Command devices
Rose
von
Projekt-Nr.
Kunde
Blattinhalt
01.02.12
Pfeiffer
29.07.15
Universal Control Unit
FST-75/150
260-2210-002 EN06
8
Contacts e.g. for warning
beacon, flashing lamp, failure
indicator, position indicator.
Configuration of relays with
aid of FST menu.
-K3
-K4
Control panel outside
Optional connection outside:
-K5
-K6
-K7
-K8
red
green
red
green
Traffic outside
Traffic inside
L1
N
Radio remote control or cable
traction switch.
Contact sequence is
selectable:
open-stop-close or
open close by menu 2.5
Terminals 17+18:
24VDC power supply
for external loads,
500mA max!
3
1
2
5
4
6
-X7
13
15
16
14
20
19
7
8
9
10
11
12
Adjust function of relays with Menu 5.1 - 5.4
17+
18-
CLOSE
OPEN
STOP