ADICOS HOTSPOT-1000
410-2410-001 EN12
DISPOSAL
Temperature dif-
ferential [°C]
between object
and device (dT)
Absolute Accuracy
Relative Accuracy [°C]
(pixel-pixel)
180 – 500
< 20 % or < 30 °C
< 10
Deviation
Averaging method (depending
on detector configuration)
Deviation
Average of ten measurements
Typically 1 °C
Maximum value of ten measurements
Typically 3 °C
With the model 0 – 500 °C
Typically 10 °C
10.3 Purge Air Requirements
Air quality grade required for purge air
Dust
Class 2
Water content
Class 3 (-20 °C dewpoint)
Oil content
Class 2 ( < 0.1 mg/m³)
Required air flow rate
In dusty, settled air
2 - 3 l/min
In dusty, flowing air
> 8 l/min
Testing is advisable in severely turbulent air.
11 Disposal
Return the device to the manufacturer when it reaches the
end of its serviceable life. The manufacturer will ensure that
the components are disposed of properly, in an environ-
mentally friendly manner.