Page 33
Setting up 3D Collection
Signal Process, Output Options, and System Options
Go through the regular steps for 2D data collection as described in the previous section.
3D Mode - Config Grid
Begin by configuring the size of the grid and separation of transects.
X – Start: Grid coordinate where data collection will begin in the X-Axis.
X – End: Grid coordinate where data collection will end in the X-Axis.
Y – Start: Grid coordinate where data collection will begin in the Y-Axis.
Y – End: Grid coordinate where data collection will end in the Y-Axis.
X – Line Spacing: Separation between transects collected in the X-Direction.
Y – Line Spacing: Separation between transects collected in the Y-Direction.
Collection Method (Bottom Pane)
Toggle between Normal and Zig-Zag data collection for the X and Y directions.