UtilityScan DF Quick Start Guide
Page 26
Focus On:
Only available when Migration is turned off.
1
Using the stylus pen, place the cross-hair on a hyperbola.
2
Tap Focus On. A vertical slider will appear to the right of the data.
3
Using the stylus pen and the vertical slider, match the Focus On
hyperbola with a hyperbola on the screen.
4
Select either Set Focus or Focus Off:
Set Focus to accept the hyperbola. This will change the
dielectric value.
Focus Off to cancel this process.
Add Target:
Only available when both horizontal and vertical
cursors are visible.
1
Using the stylus pen, place the cross-hair on a hyperbola.
2
Tap Add Target. A vertical color tablet will appear.
3
Select the desired color that matches the known or potential use
of the target.