- 28 -
SMCIP 401 ASI
Spectral position – inverting the user signal
For exceptional cases and "older" digital receivers, the spectral position of the
user signal can be inverted "
NEG
". The default setting is "
POS
".
• Use
</>
to place the cursor under "
POS
".
• Use
+/–
to set the spectral position to "
NEG
".
Code rate (FEC):
—> During a transmission data can be lost or changed. To recover this
data redundancy is added to the signal to be transmitted (forward
error correction – FEC). The factor of the quantity of redundancy
contained in the bits transmitted is called code rate.
Using the setting "
7/8
" you can get the highest output data rate at
lowest error correction.
• Use
</>
to place the cursor under "
7/8
".
• Use
+/–
to set the required code rate ("1/2", "2/3", "3/4", "5/6", "7/8").
• Press the
MODE
button.
—> Return to the "output parameter" main menu – "
OUTPUT
".
• Press the
MODE
button.
—> The "ASI input selection" main menu – "
ASI
" is activated.
asi
inPut
seleCtion
In this menu you select whether you would like to use the ASI input instead of
tuner D.
INPUT
off
ASI
INPUT
=> D
ASI
INPUT
=> OUTPUT
ASI
• Press
+/–
to select …
…
off
means Tuner D ("ASI
off
").
…
=> D
means ASI input instead of tuner D (ASI
=> D
).
…
=> OUTPUT
means "transparent mode" –
only the transport stream from
the ASI input is unmodified transferred
(no table modifications etc.)
to the
modulator.