- 30 -
PADA 5100
—> "
all
" - all stations are used.
"
cascaded
" - setting for the "downstreamed" PADA 5100
when using several PADA 5100 cascaded – observe the following
hints about the service IDs (SIDs) as well as chapter "cascading"
(page 37).
"
first
" - only the first station of the transport stream (PAT) is used.
"
manual
" - the additional submenu "Manually selection" will be
displayed next. All stations are deactivated and must activated in
submenu "Manually selection"!
If "
PC => CLEAR
" is displayed, special settings via PSW 1000 are
done before. Use button
to delete this settings!
Service IDs (SID)
Dependent on the "multiplex mode" setting (page 19) new SIDs will be
assigned to the selected services.:
MUX-MODE "manual" - only SIDs which are present twice will be
changed.
MUX-MODE "fixed" - all SIDs will be changed.
At station filter settings "all", "first" und "manual" the assignment of the
SIDs is done "dynamically" according to the following scheme :
SID standard 16 Bit:
Input
1
- services 1 … 64—> SIDs
1
01 …
1
64
Input
2
- services 1 … 64—> SIDs
2
01 …
2
64
Input
3
- services 1 … 64—> SIDs
3
01 …
3
64
Input
4
- services 1 … 64—> SIDs
4
01 …
4
64
Input
5
- services 1 … 64—> SIDs
5
01 …
5
64
—> If more than 64 services per input are selected, this "overflow" is
assigned from SID 601 upwards.
SID standard 8 Bit:
Input
1
- services 1 … 9 —> SIDs
1
1 …
1
9
Input
2
- services 1 … 9 —> SIDs
2
1 …
2
9
Input
3
- services 1 … 9 —> SIDs
3
1 …
3
9
Input
4
- services 1 … 9 —> SIDs
4
1 …
4
9
Input
5
- services 1 … 9 —> SIDs
5
1 …
5
9
—> At setting "
cascaded
" the assignment of the SIDs is done "statical-
ly". Therefore an example is shown in chapter "
cascading
" page 37.