- 36 -
HMPT 1000 C
s
ubstitute
signal
in
the
Case
of
an
inCorreCt
inPut
signal
You use this menu to set whether a QAM signal filled with "
Null Packets
", a
QAM signal filled with null packets and self-made tables "
Tables
" or a "
Single
Carrier
" signal should be provided as an output signal whenever an incorrect
input signal occurs. Self-made tables are transmitted furthermore.
Bx 4A
Null Packets
FAILURE
• Use the
buttons to set the output signal required.
• Press the
button.
—> The "Transport stream/ORGNET-ID" – "
TS/ONID
" menu is activated.
t
r ansPort
strea m
/ orgnet-id
If the stations of a transponder are split into the transport streams of the chan-
nel strips "
A
" and "
B
", one of the both transport streams a new identification
must be allocated to realise the channel search of the settop boxes connected
without mistakes.
If the ORGNET-ID is changed a new NIT must be generated (page 37).
Bx 4A
0x0001,0100
TS/ONID
off
• Use the
buttons to position the cursor under the digit of the hexadeci-
mal number to be set.
• Press
to set the respective digit of the hexadecimal number.
• Repeat the procedure by the quantity of the digits to be set.
• Using the button place the cursor under "
off
" and switch "
on
" the trans-
mitter identification using the
buttons.
—> By pressing the
button you return to the hexadecimal number
setting.
• Press the
button.
—> The "Network Information Table" – "
NIT