GSM SMS Controller Alarm &GSM House Alarm System&
GSM Telemetry Units & GSM GPRS Logging System
and smoke detectors, etc.) and some detectors indoor not in working status (e.g.: the detectors installed in the living room, bed
room, etc.).
4) The S120 can accept total 16 wireless learning code detectors to 16 wireless zones, each zone can be assigned one learning
code wireless detector, and accept lots of PT2262/2272 fixed code wireless detectors in each zone. The name of the zone can be
renamed by SMS Command. And 5 remote keys.,
5) Wireless Zone Serial Number, Default Zone Name and Zone Attributes Table.
Zone SN.
Default Zone Name
Default Zone Attribute
01
Intrusion from Entry Door
Normal
02
Intrusion from Living Room
Normal
03
Intrusion from Bed Room 1
Normal
04
Intrusion from Bed Room 2
Normal
05
Intrusion from Bed Room 3
Normal
06
Intrusion from Front Balcony
Normal
07
Intrusion from Behind Balcony
Normal
08
Intrusion from 1F Window
Normal
09
Intrusion from 2F Window
Normal
10
Intrusion from Left Fence
Normal
11
Intrusion from Right Fence
Normal
12 Medical
Button
Alarm
24-Hour zones, in arm or disarm or stay mode, once the detector in these
zones triggered will alarm.
13 Gas
Leakage
Alarm
14 Smoke
Fire
Alarm
15 Watchdog
alarm
Watchdog Zone, in arm or disarm or stay mode, once the detector in this
zone triggered in the preset time, will not alarm, if the detector hasn’t been
triggered in the preset time, will alarm.
16 SOS
Help!
SOS zone, in arm or disarm or stay mode, once the detector in these zones
triggered will alarm immediately. not drive the siren.
Notice:
The Additional Panic Button, and the SOS button on the Keyboard and remote key is the same attribute with the
SOS zone.
6.2.2.2 Wired Zones Set
Notice:
1)
The Nodes Type NC,NO,EOL should reference the wired input detector type. The Default is NC and we short all of the inputs by
wires, if you want to contact wired detectors, then please replace the short wires by wired detectors directly. The no-use input,
please remain them in short-circuited by wires. Please see
8.4 Install the Wired Detectors and Electricity
equipments
2) Zones’
Attribute
definition
of the wired zone is the same as the wireless zone.
3) The S120 can accept total 19 wired detectors to 19 wired zones; each zone can be assigned one wired detector, and renamed it
by SMS Command. The IN20 is 24 Hours Zone and special for Tamper Switch.
4) Wired Zone Serial Number, Default Zone Name and Zone Attributes Table.
Zone SN.
Default Zone Name
Default Zone Attribute
01
Outer Door Opened
Normal
02
Intrusion from Left Fence
Normal
03
Intrusion from Right Fence
Normal
04
Intrusion from Front Fence
Normal
1.Nodes Type
2.Zones Attributes
---To setup the wired inputs type.
---To setup the wired input’s attribute.