1) The RF Code Query function is for check the wireless detector transmission. You can enter this submenu, then triggered the
wireless detector, if in the LCD can display some codes, means the wireless detector can transmit wireless signal.
6.2.2 Setup
6.2.2.1 Add/Del RF Parts
Notice:
1) Zones’
Attribute
definition:
Zones’ Attribute
Definition
Normal
The detectors with this type triggered will alarm in Armed mode and not alarm in disarmed mode.
Stay
In Stay mode, the detectors with Stay type triggered will alarm, the detectors with Normal type triggered will
not alarm.
24-Hour Zone
In any mode, the detectors with this type triggered will alarm.
Watchdog
In the starting time point and ending time point, the detectors with this type triggered will not alarm, if the
detectors hasn’t been triggered, will make alarm.
SOS Help!
In any mode, the detectors with this type triggered will alarm but not drive the siren.
Alarm Action: when Alarm occurrence, the system will Automatically dial the Pre-set Auto-Dial Tel. Numbers for 3 times one by
one, and Send SMS to the Pre-set SMS Alert Numbers, in the meantime, will drive the siren for total 2 minutes with every 20
seconds stop 1 second to extend the siren’s life. and close the link-Output relay for 4 minutes.
2) After you enter the menu, the attribute of the zone will be displayed in the LCD, if this zone has been assigned wireless detector,
will display “V”. If hasn’t been assigned wireless detector, means this zone is empty, you can assign new wireless detector to this
zone. Press Up or down button on the keyboard to check the other Zones. Press Enter to edit it. After you pressed the Enter
button, you can select the zone attribute, and then press Enter, you can see “Turn on the device” or “Please trigger the new
wireless detector”. Then following the instruction to add the new wireless detector to the S120. For Remote control, it will display
VVVV if the unit has been assigned remote control. Both of them you can press Enter to re-assign new wireless detector or
remote keyto replace the existence one.
3) In the Edit RF Parts you can edit the attribute of the detectors. If the system is under Stay Mode (Also said At House or Partial
Armed), the detector set as Normal triggered will not alarm, the detector set as Stay triggered will Alarm. If the system is under
Armed Mode, then all RF detectors triggered, will alarm. This is very important to remember the detector types of the system. This
function is very useful when you at house and need some detectors in working status (E.g.: the detector installed outer and gas
1. Add/Del RF Parts
2.Wired Zones Set
3.Basic Setting
4. Advanced Setting
1.Edit RF Zone
2.Edit Remote Ctrl
3. Remove All
---To add or remove wireless detectors or remote keys and edit their attributes.
---To setup Wired Zone parameters of the system.
---To setup basic parameters of the system.
---To setup the advanced parameters of the system.
---To setup the zone’s attribute and add new wireless detectors to specificities zone.
---To add new remote Keys.
---To remove all registered wireless sensors and remote keys.