Idea Moving Led 100
17
200-231
Rainbow colours
232-255
Crossfading colours from slow to fast
Lamp on/off, reset, internal programs:
0-79
Normal
80-84
All motor reset
85-87
Scan motor reset
88-99
No function
100-119
Internal program 1 (secne1~8 of EEPROM)
120-139
Internal program 2 (secne9~16 of EEPROM)
140-159
Internal program 3 (secne17~24 of EEPROM)
160-179
Internal program 4 (secne25~32 of EEPROM)
180-199
Internal program 5 (secne33~40 of EEPROM)
200-219
Internal program 6 (secne41~48 of EEPROM)
220-239
Internal program 7 (secne49~56 of EEPROM)
13
13
240-255
Music Control (secne of Program 1)
ERROR MESSAGE
When you turn on the fixture, it will make a reset first. The display may show “XXer” while there are
problems with one or more channels. “XX” stands for channel 1, 2, 3,etc who has the testing sensor for
positioning.
For example, when the display shows “Red Er”, it means there is some error in channel 1. If there are some
errors on channel 1, channel 2, channel 5 at the same time, you may see the error message “Red Color Er”,
“Green Er ”, “Pan Er” flash repeated for 5 times, and then the fixture will generate a reset signal, all the
stepper reset. If the fixture remain error message after performing reset more than 3 times, it will detect
whether the fixture has more than 3 errors. If the fixture has more than 3 errors (including 3 errors), all the
channels can not work properly; but if the fixture has less than 3 errors, only the channels which have errors
can not work properly, others can work as usual.
PAN- movement Er
(PAN-yoke movement error) This message will appear after the reset of the fixture if the yoke’s
magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the stepping-motor is defective
(or its driving IC on the main PCB). The PAN-
movement is not located in the default position after the reset.
TILT- movement Er
(TILT-head movement error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepping-motor is defective
(or its driving IC on the main PCB). The TILT-
movement is not located in the default position after the reset.