5. Operating Controls
Vision Control Panel Layout
Figure 5A
The vision control system is a state of the art dryer controller used on several GSI drying products.
The vision control can operate any dryer in either a batch or a continuous flow mode. All operating
instructions for the TM-Series dryer describes
continuous flow
operation only.
Control Power Switch
The vision control system is turned ON or OFF with this switch.
NOTE:
This switch does NOT disconnect the power that is present at the breakers, contractors,
transformers, fuses or other electrical components found in the control or power box. Turn the main
disconnect handle located on the power box to the OFF position prior to servicing any of the
installed components.
Fan Switch
The fan is turned ON or OFF with this switch. Turning the switch to the ON position will turn the fan ON.
Turning the switch to the OFF position turns the fan OFF. The light inside the switch will illuminate
whenever the air pressure sensor senses air movement through the fan. (
NOTE: The fan AUTO position
is not used for continuous flow operation.
)
Heater switch
Fan switch
Load auger switch
Unload auger switch
Operator light switch
Control power switch
Stop switch
Start switch
Meter system speed
Touch screen