27
zero illumination status manually
.
Note
:
the displayed icon and function vary with the type of the video camera.
4.2
Common failure and its solution
Failure Cause
Solution
Check if there is power
replace
Failure in engineering line
eliminate
No action, and
picture after
powered
Power line misconnected
correct
Mechanical failure
correct
Video camera tilted
Put it straight
Self check is
abnormal, there
is picture, but
with block
Insufficient power of power supply
Replace power
supply,
Put the power
supply near the
spherical device
Wrong connected video line
Correct
Poor contact of video line
eliminate
Self check acts
normally, but no
picture
Damaged video camera
replace
Wrong connected control signal
line
correct
Wrong setting of video camera
code
Re-set code
Self check
succeed but not
controllable
Wrong protocol
Correct
Unstable picture
Poor contact of video line
Insufficient power of power supply
Eliminate
replace
Insufficient power of power supply,
causing code loss
Replace power
supply
Self check is abnormal
Re-power
Spherical device
out of control,
unstopping
operation
Wrong operation of main machine
Re-power
Summary of Contents for GS-PTZ-1010