4. General Information
PNEG-2175CE
CE Compliant Sampler - Model GCE 45 and GCE 90
19
Ignition Hazard Assessment - GCE Samplers
Guarding of Moving Parts
GCE samplers have hazardous moving parts which present a risk of serious injury when unguarded.
The samplers operate under automatic control and may start unexpectedly and without warning.
1. Guards are provided to enclose all moving parts except those involved in the sampling process.
2. Moving parts involved in the sampling process shall be made inaccessible at installation by enclosing
both the inlet and outlet of the sampler such that the moving parts cannot be reached by any part of
the human body.
3. Generally this is achieved by close coupling the sampler inlet and outlet to the upstream and
downstream conveying system.
4. Where this is not suitable (ex: open hopper inlet), the installer must ensure access to the moving parts
is restricted in accordance with EN ISO 13857 or through other methods (ex: interlocking controls).
5. Under certain circumstances it may be necessary to remove guards. Only do this when the sampler
and other associated equipment is isolated and locked out from the power supply.
6. Never operate the sampler with the guards removed.
Possible Ignition
Sources
Equipment
related Yes/No
Reason
Controls
Hot Surfaces
Yes
Sliding friction of moving parts on static parts
Surface temperature of gearbox and motor
Slipping torque tamer clutch
Bearing temperatures
Constructional safety
Control of ignition sources
Surface temperature control
Overrun timers
Mechanical Sparks
Yes
Single impact of mal-adjusted moving part.
Chain/sprocket failure
Sampling incorrect materials, prone to impact
sparks
Constructional safety
Operator’s manual instruction on
correct use
Flames, Hot Gases
No
None present
Electric Sparks
Yes
Potential arcs at electrical connections, in motors
and switches.
Static electricity sparks from non-conductive
surfaces.
Constructional safety
Control of ignition sources
Electrical controls design and
installation to EN 60204
Stray Electric
Current and Cathodic
Corrosion Protection
No
None present
Static Electricity
Yes
None present
Lightning
No
To be addressed on specific installation location
To be addressed on site
Electromagnetic
Waves
No
None present
Ionising Radiation
No
None present
High Frequency
Radiation
No
None present
Ultrasonics
No
None present
Adiabatic
Compression
No
None present
Chemical Reaction
No
None present