8. Wiring Diagrams for Swine Application
16
PNEG-1945
IR Plus Feed Sensor
Wiring Diagram for Smart-Flex to IR Plus Feed Sensor
RELAY BOX (FLX-4778)
GND
L1
L2
208-230VAC
POWER SUPPLY
FLEX-FLO
MOTOR
GND
M2
M1
IR PLUS FEED SENSOR (FLX-5262)
SMART-FLEX (FLX-4629LS
)
TOP
TO ALARM SYSTEM
(IF USED)
IN - RS485
CA
BLE (IF
USE
D
)
TO NETWORK MASTER
COMMUNICATION
BOTTOM
OUT - RS485 CABLE (IF USED)
TO NETWORK MASTER
COMMUNICATION
CORD (FLX-5265)