36
PNEG-1807CE
CE Compliant 16"-24" Bucket Elevator Platform and Ladder “X” Series
7. Rest Platform
Chapter 7: Rest Platform
Rest Platform Tie Angles to Bucket Elevators
1. Install rest platform tie angles to the lower trunking on both the ladder side and non-ladder side of the
trunking. Use 1/2" x 1" bolts through the bolt holes indicated for the bucket elevator size being
installed.
NOTE:
Bolt hole starting location on left side of tie angle is marked with the bucket size.
Figure 7A Tie Angle with Etched Numbers
Figure 7B 16" Rest Platform Tie Angle Bolt Locations - Ladder Side
Ref #
Part #
Description
Ref #
Part #
Description
A
GECT1640FCRPX2 16"-24" Rest Platform Tie Angle
C
S-8506 1/2" Flange Nut
B
S-7935
1/2" x 1" Bolt
D
Hole Marked 24" 16". Use Side Marked 16".
Tie Angle Etched Identification Holes
16" Tie Angle Bolt
Locations - Ladder Side
Down-leg
Up-leg