HT E11 / E12 Ethernet Terminal Instruction Manual 

 

PROPER USE AND SAFETY REQUIREMENTS 

 

 

 

 

 

Cut  all the  power  when  connecting  and  disconnecting  the  device 

to a panel. 

 

 

 

 

 

 

 

 

Do  not  clean  the  device  with  a  solvent  or  similar  material.  Only 

use a dry cloth. 

 

 

 

 

 

 

 

Please do not intervene to the device when a technical problem is 

encountered and get in contact with a technical service within the 

shortest time. 

 

 

 

 

 

 

 

 

 

If  the  warnings  are  not  taken  into  account,  our  company  or  the 

authorized  dealer  shall  not  be  held  responsible  for  the  negative 

consequences. 

 

 

 

 

 

 

 

Do  not  dispose  in  the  trash,  the  device  must  be  delivered  to  the 

collection  centers  (electronic  device  recycling  centers).  It  should 

be  recycled  or  disposed  of  without  harming  human  health  and 

environment. 

 

 

 

The installation, assembly, activation and operation of the device 

should  be  done  and  used  by  only  expert  professionals  and  in 

accordance with safety regulations and instructions. 

 

 

 

The  device  operates  with  current  transformers.  Do  not  strictly 

leave current transformer tips unattached. Dangerous high voltage 

can occur.

 

Summary of Contents for GA3101

Page 1: ...ER SAN ve T C LTD T kitelli OSB Mah YT kitelli Teknopark Sok No 1 2B1 2B7 2B8 2B9 Ba ak ehir stanbul Phone 90 212 438 80 24 Fax 90 212 438 80 25 Technical Support Phone 90 212 438 61 17 Mobile Phone 9...

Page 2: ...6 2 2 How to Use Authorization Code 7 3 METER COMMUNICATION CONNECTIONS 7 3 1 Optical Port Connection 7 3 2 Makel RS 232 Communication Connection 8 3 3 Makel K hler Viko RS 485 Communication Connectio...

Page 3: ...account our company or the authorized dealer shall not be held responsible for the negative consequences Do not dispose in the trash the device must be delivered to the collection centers electronic...

Page 4: ...utes dynamic IP with DHCP the device will automatically try to access the internet by receiving IP If the DHCP is not available the device must be connected to a computer via USB port and the suitable...

Page 5: ...itecture which does not require Static IP In cases which Static IP is required the necessary settings can be made via USB interface of the device The operating ambient temperature of the device is bet...

Page 6: ...nergizing after checking all the connections for the last time 6 After a while by entering SmartPower Energy Monitoring System you can check whether your device is sending data or not If you have no i...

Page 7: ...em Authorization button and enter the information of Authorization Code paper which comes out of the product box 3 If the information is entered correctly the device will be automatically transferred...

Page 8: ...NOTE When placing the optical reader on the meter make sure the arrow mark on the label points to upward direction 3 2 Makel RS 232 Communication Connection Cable Color Brown Green Yellow White Termi...

Page 9: ...HT E11 E12 Ethernet Terminal Instruction Manual 9 3 3 Makel K hler Viko RS 485 Communication Connection 3 4 Elektromed Luna RS 485 Communication Connection Figure 3 4 Figure 3 5...

Page 10: ...HT E11 E12 Ethernet Terminal Instruction Manual 10 3 5 Elster RS 485 Communication Connection There are two RS 485 terminals in some models of Elster meters Figure 3 6 Figure 3 7...

Page 11: ...EMH RS 485 Communication Connection 3 7 Landis RS 485 Communication Connection NOTE In order to read Landis Meters via RS 485 the technical support line must be called and serial number of the meter...

Page 12: ...nected to B The connection of the different named devices is showed below NOTE The Modbus addresses and the types of the devices that connected to the modem must be defined by entering the setting pag...

Page 13: ...HT E11 E12 Ethernet Terminal Instruction Manual 13 4 2 Klemsan Relay REMO Q and RAPIDUS Terminal Connection 5 SELECTION TABLE Table 5 1 Figure 4 2...

Reviews: