10.1 u
pdatinG
soft ware
via
pC
The RS 232 interface of the control unit enables you to use a PC or a notebook
and the "
BE-Flash
" software to update the operating software of the control
unit.
You can find the "
BE-Flash
" software and the current operating software of the
head-end station’s control unit at the website "
www.mygss.eu
".
• Use a "one-to-one cable" (see fig. 19 for circuit) to connect the control unit’s
RS 232 interface and the PC.
9-pin
D-SUB socket
9-pin
D-SUB plug
1
2
3
4
5
6
7
8
9
1
2
3
4
5
6
7
8
9
Fig. 19
• Start the "
BE-Flash
" software and update the software of the control unit.
10.2 u
pdatinG
the
soft ware
via
seCond
Control
unit
In this type of update, the current version of the software in one control unit
(master) is transferred to the control unit you want to update (slave).
r
emovinG
m aster
Control
unit
∞
§
7
1
2
• Switch off the head-end station.
• Disconnect snap-in hook
∞
in the
direction of arrow "
1
".
• Pull control unit
7
in the direction of
arrow "
2
" on the bottom and disconnect
from snap-in hook
§
.