- 9 -
STC 816
When the head-end station is shipped from the factory, the default setting for
the RF output level of the output collector is -3 dB. You can use the software of
the control unit to program the master output level of the head-end station.
The software version of the control unit appears on the two-line LC display after
switching on the head-end station.
If the inner temperature of the head-end station exceeds the permissible tem-
perature of 65 °C when operating, a message appears in the display instead
of the standby menu. This message contains the maximum measured tempera-
ture and the number of the head-end station.
The display also supports dialogue guidance when programming the head-
end station. Use the buttons of the control unit to program the head-end sta-
tion. You can also use the PSW 1000 software and the HRCU 8 / RCU 1
management unit to program the head-end station.
The RS 232 interface of the control unit enables you to use a PC or a note-
book and the "
BE-Flash
" software to update the operating software of the
control unit. You can find the current operating software for the control unit,
the software "
BE-Flash
" and the current assembly instructions on the website
"
www.mygss.eu
".
3
o
verview
3.1 f
ront
Cover
2
2
1
Fig. 1
1
Locking screws
2
Mounting screws
—>
To maintain compliance with the EMC regulations, the head-end sta-
tion must not be operated without this front cover.