![Grundig GCI-F0505B Owner'S Manual Download Page 56](http://html1.mh-extra.com/html/grundig/gci-f0505b/gci-f0505b_owners-manual_2273078056.webp)
- Upload Image by E-Mail:
After selecting this item, the Administrator can assign an e-mail address and configure various parameters as
shown in the picture below. When a motion is detected, event images will be sent to the appointed e-mail address.
The <Pre-trigger buffer> recording function allows users to check what happened to trigger the alarm. The pre-
trigger buffer time range is from 1 to 20 frames.
On the other hand, the <Post-trigger buffer> is for uploading a certain amount of images after the alarm input is
triggered. The post-trigger buffer time range is from 1 to 20 frames.
Check the box <Continue image upload> to upload the triggered images during a certain time or keep uploading
until the trigger is off.
- Select <Upload for __sec> and enter the duration in the blank. The images of the duration will be uploaded
via
when the alarm input is triggered. The setting range is from 1 to 9999 seconds.
- Select <Upload while trigger is active> to keep the images being uploaded
via E-Mail
while the trigger is active,
i.e. until the alarm is stopped.
Set the Image frequency as the upload frame rate. The setting range is from 1 frame to 15 frames.
NOTE: Make sure SMTP or FTP configuration has been completed. See section 9.5. Mail and 9.6. FTP for further
details.
- Send HTTP notification:
Check this item, select the destination HTTP address, and specify the parameters for event notifications when
<Motion Detection> is triggered. When an alarm is triggered, the notification can be sent to the specified HTTP
server.
For instance, if the custom parameter is set as ”action=1&group=2”, and the HTTP server’s name is”
http://192.168.1.200/admin.php”, the notification will be sent to the HTTP server as
”http://192.168.1.200/admin.php? Action=1&group=2” when an alarm is triggered.
File Name :
The uploaded image’s filename format can be set in this section. Please select the one that meets your
requirements (please see the section "File Name" in 9.8. 'Application (Alarm Settings)').
Save :
Click on the "Save" button to save all the Motion Detection alarm settings mentioned above.
54
English
Summary of Contents for GCI-F0505B
Page 2: ......
Page 13: ...11 English...
Page 16: ...14 English...
Page 19: ...17 English...
Page 22: ...20 English...
Page 100: ...98 English...