11.10. Camera - Misc 1
In Camera—Misc (Miscellaneous Setups) 1, users can set various camera parameters including Backlight
Compensation (BLC), Sharpness, Exposure Compensation (ExpComp), Image Flip, Digital Zoom and the ICR
function. Each setting is specified as follows:
BLC :
Users can choose to activate or disable the BLC function. Click on the button “Set” to save the setting.
Sharpness :
Increasing the sharpness level can make the image look sharper; it especially enhances the object’s edges. The
Sharpness value is adjustable from 1 to 15. Click on the button <Set> to confirm the setting.
ExpComp :
Users can define the value of Exposure Compensation. The value ranges from 1 to 15.
Flip :
Users can track an object continuously when it passes through under the Dome Camera with setting Flip to
Mechanical (M.E.) mode or Digital Flip (Image) mode.
NOTE: The Flip setting can only be controlled manually. If a Preset Position or a point for another function (e.g.
Sequence) is set in a position that can only be reached through the FLIP motion: when the Flip function is turned
off, the position cannot be reached anymore.
NOTE: To make the Dome Camera tilt between a specific range, such as -10° to +100° or -10° ~ +190°, please go
to the Tilt Range setting page to set the tilt angle range. Otherwise, the Dome Camera will tilt 90° as default
setting.
- M.E. Mode:
M.E. is a standard mechanical operation. As the Dome Camera tilts to the maximum angle, it will pan 180°, and
then continue tilting to keep tracking an object.
- Image Mode:
IMAGE represents digital IMAGE FLIP, which enables users to keep tracking objects seamlessly. In this mode,
almost no delay occurs, compared to M.E. mode.