background image

5 / 8

4. Dismantling and assembly

General information

Position numbers of pump part (figures) refer to exploded views, sectional drawings and parts lists.

Before dismantling

• Disconnect the electricity supply to the motor.

• Remove the electric cable in accordance with local regulations.

Before assembly

O-rings should always be replaced when the pump is overhauled.

• Clean and check all parts.

• Order the necessary service kits.

Replace defective parts by new parts. 

Disposal

This product or parts of it must be disposed of in an environmentally sound way:

1. Use the public or private waste collection service.

2. If this is not possible, contact the nearest Grundfos company or service workshop. 

4.1 Removing the motor

1. Loosen the strainer (pos. 84) by inserting a screwdriver between the bottom part (pos. 50) and the suction strainer 

and turning the screwdriver.

2. Remove the screws (pos. 84b) and the bottom part (pos. 50).

Fig. 3. 

Removing the bottom part

3. Remove the O-ring (pos. 37a) and the diaphragm (pos. 58).

4. Remove the screws (pos. 36).

5. Remove the pump sleeve (pos. 55a) by holding the sleeve and pressing the impeller.

6. Moisten the O-rings (pos. 37 and 48a) and remove them.

7. Pull the motor (pos. 48) out of motor sleeve (pos. 55).

4.2 Replacing the capacitor

1. Remove the motor, see 

4.1 Removing the motor

.

2. Pull the capacitor (pos. 161) out of the retainer (pos. 160).

3. Pull of the cable terminals and fit the new capacitor.

4. Fit the motor, see 

4.5 Fitting the motor

.

4.3 Replacing the impeller

1. Remove the motor, see 

4.1 Removing the motor

.

2. Remove the retainer (pos. 160) with capacitor so that the shaft end is visible.

3. Insert a screwdriver into the slot in the shaft end and remove the impeller (pos. 49), nut (pos. 67) and washer (pos. 

66) as well as the V-ring (pos. 159) in CC7 and CC9.

4. Keep the screwdriver in the slot and fit the washer, V-ring, if any, the new impeller and the nut.

5. Make sure that the nut is positioned in the "seat" of the impeller.

6. Fit the retainer (pos. 160) with capacitor.

7. Fit the motor, see 

4.5 Fitting the motor

.

TM

03

 1

1

12 

10

05

Summary of Contents for Unilift CC 5 M1

Page 1: ...t finding 3 3 Cleaning the pump 4 3 1 Cleaning the suction strainer 4 3 2 Cleaning the impeller 4 4 Dismantling and assembly 5 4 1 Removing the motor 5 4 2 Replacing the capacitor 5 4 3 Replacing the...

Page 2: ...11 Approvals 5 Product number 12 Motor input power 6 Production code 13 Maximum installation depth 7 Full load current 14 Supply voltage Example Unilift CC 7 A1 Pump range Type Maximum head m Operati...

Page 3: ...nt cooling b Pump partly blocked by impurities or blocked Clean the pump see 3 2 Cleaning the impeller c Water level too low when the pump is started The pump cannot self prime Move the pump to a posi...

Page 4: ...he bottom part pos 50 and the suction strainer and turning the screwdriver 2 Remove the screws pos 84b and the bottom part pos 50 Fig 2 Removing the bottom part 3 Remove and clean the O ring pos 37a a...

Page 5: ...g 3 Removing the bottom part 3 Remove the O ring pos 37a and the diaphragm pos 58 4 Remove the screws pos 36 5 Remove the pump sleeve pos 55a by holding the sleeve and pressing the impeller 6 Moisten...

Page 6: ...50a and pull the cable entry into position in the motor sleeve The cable entry must now be fixed in the retainer in the motor sleeve It must not be possible to pull the cable any longer The cable entr...

Page 7: ...upwards during the measurement Fig 4 Wiring diagram Pump type Winding resistancea 10 a The table values do not include the cable Resistance in cable 2 x 10 m approx 1 Auxiliary winding Main winding Un...

Page 8: ...8 8 6 Drawing TM03 1101 1005...