10.6 Electrical data
10.6.1 Grundfos submersible motors, 60 Hz
Grundfos submersible motors, 60 Hz
Hp
Ph
Volt
[V]
SF
Circuit breaker or fuses
Amperage
Full load
Max. thrust
[lbs]
Std.
Delay
Start
[A]
Max.
[A]
Eff.
[%]
Power factor
4-inch, single-phase, 2-wire motors (control box not required)
0.5
1
115
1.60
35
15
55.0
12.0
62
76
900
0.5
1
230
1.60
15
7
34.5
6.0
62
76
900
0.75
1
230
1.50
20
9
40.5
8.4
62
75
900
1
1
230
1.40
25
12
48.4
9.8
63
82
900
1.5
1
230
1.30
35
15
62.0
13.1
64
85
900
4-inch, single-phase, 3-wire motors
0.5
1
115
1.60
35
15
42.5
12.0
61
76
900
0.5
1
230
1.60
15
7
21.5
6.0
62
76
900
0.75
1
230
1.50
20
9
31.4
8.4
62
75
900
1
1
230
1.40
25
12
37.0
9.8
63
82
900
1.5
1
230
1.30
35
15
45.9
11.6
69
89
900
2
1
230
1.25
35
20
57.0
13.2
72
86
1500
3
1
230
1.15
45
30
77.0
17.0
74
93
1500
5
1
230
1.15
70
45
110.0
27.5
77
92
1500
4-inch, three-phase, 3-wire motors
1.5
3
230
1.30
15
8
40.3
7.3
75
72
900
1.5
3
460
1.30
10
4
20.1
3.7
75
72
900
1.5
3
575
1.30
10
4
16.1
2.9
75
72
900
2
3
230
1.25
20
10
48
8.7
76
75
900
2
3
460
1.25
10
5
24
4.4
76
75
900
2
3
575
1.25
10
4
19.2
3.5
76
75
900
3
3
230
1.15
30
15
56
12.2
77
75
1500
3
3
460
1.15
15
7
28
6.1
77
75
1500
3
3
575
1.15
15
6
22
4.8
77
75
1500
5
3
230
1.15
40
25
108
19.8
80
82
1500
5
3
460
1.15
20
12
54
9.9
80
82
1500
5
3
575
1.15
15
9
54
7.9
80
82
1500
7.5
3
230
1.15
60
30
130
25.0
81
82
1500
7.5
3
460
1.15
35
15
67
13.2
81
82
1500
7.5
3
575
1.15
30
15
67
10.6
81
82
1500
10
3
460
1.15
50
30
90
18
81
80
1500
Single-phase motors (thermally protected): Use with
approved motor control that matches the motor input in full
load amperes.
Three-phase motors: Use with approved motor control
that matches the motor input in full load amperes with
overload element(s) selected or adjusted according to
control instructions.
39
English (US)
Summary of Contents for SP 1100S