background image

En
gl

is

h (
G

B)

2

English (GB) 

Installation and operating instructions

Original installation and operating instructions

CONTENTS

Page

1.

General information

3

1.1

Symbols used in this document

3

1.2

Qualification and training

3

1.3

Safety instructions for the operator/user

3

1.4

Safety of the system in the event of a 

failure in the dosing pump

4

1.5

Dosing chemicals

4

1.6

Diaphragm leakage

4

2.

Storage and handling

5

2.1

Storage

5

2.2

Unpacking

5

2.3

Transport

5

3.

Product introduction

5

3.1

Applications

5

3.2

Improper operating methods

5

3.3

Symbols on the pump

6

3.4

Nameplate

6

3.5

Type key

7

3.6

Product overview

8

4.

Technical data / Dimensions

9

4.1

Technical data

9

4.2

Technical data for CIP (Clean-In-Place) 

applications

11

4.3

Dimensions

11

5.

Assembly and installation

12

5.1

Pump assembly

12

5.1.1 Requirements

12

5.1.2 Aligning and installing the mounting plate 12
5.1.3 Installing the pump on the mounting plate 12
5.1.4 Adjusting the control cube position

13

5.2

Hydraulic connection

13

5.3

Electrical connection

15

6.

Startup

17

6.1

Preparing the pump for startup

17

6.2

Starting up and deaerating the pump

17

7.

Operation

18

7.1

Operating elements

18

7.1.1 Capacity adjusting knob

18

7.1.2 LEDs (DDE-B)

18

7.1.3 Keys and LEDs (DDE-AR)

19

7.2

Operation modes

19

7.2.1 Manual

19

7.2.2 Pulse

19

7.2.3 Analog

20

7.2.4 Changing the operation mode

20

7.3

Inputs/outputs

20

7.3.1 External stop

20

7.3.2 Empty and low-level signals

20

7.3.3 Relay outputs

21

7.3.4 Change settings

21

8.

Service

22

8.1

Regular maintenance

22

8.2

Cleaning

22

8.3

Perform service

22

8.3.1 Service overview

23

8.3.2 Dismantling the dosing head, diaphragm 

and valves

24

8.3.3 Reassembling the dosing head, diaphragm 

and valves

24

8.3.4 Replacing the deaeration valve

25

8.3.5 Replacing the mains cable

25

8.4

Diaphragm leakage

26

8.4.1 Dismantling the dosing head, diaphragm 

and valves in case of diaphragm leakage

26

8.4.2 Dosing liquid in the pump housing

26

8.5

Repairs

27

9.

Faults

28

9.1

Indicated faults for DDE-B

28

9.2

Indicated faults for DDE-AR

29

9.3

General faults

30

10.

Disposal

30

Read this document before installing the 
product. Installation and operation must 
comply with local regulations and accepted 
codes of good practice.

Summary of Contents for SMART Digital XL - DDE 120-7

Page 1: ...SMART Digital XL DDE From 60 to 200 l h Installation and operating instructions GRUNDFOS INSTRUCTIONS Further languages http net grundfos com qr i 98767824...

Page 2: ...al connection 15 6 Startup 17 6 1 Preparing the pump for startup 17 6 2 Starting up and deaerating the pump 17 7 Operation 18 7 1 Operating elements 18 7 1 1 Capacity adjusting knob 18 7 1 2 LEDs DDE...

Page 3: ...or user The safety instructions described in these instructions existing national regulations on health protection environmental protection and for accident prevention and any internal working operati...

Page 4: ...4 Diaphragm leakage To avoid any danger resulting from diaphragm leakage observe the following Perform regular maintenance See section 8 1 Regular maintenance Never operate the pump with blocked or s...

Page 5: ...is sucked up with a short suction stroke regardless of the current dosing flow and dosed with the longest possible dosing stroke 3 1 Applications The pump is suitable for liquid non abrasive non flamm...

Page 6: ...power supply The device complies with electrical safety class I TM06 7308 3418 P Q U Type Model f Pmax Imax 99140620 Made in France psi gph A l h Bar W IP 65 td W NEMA 4X psi gph A l h Bar W IP 65 1...

Page 7: ...PVC V C F 31U3U3FG F Front mounted change to left or right is possible Supply voltage DDE 60 10 AR PVC V C F 31U3U3FG 3 100 240 V 50 60 Hz single phase Valve type DDE 60 10 AR PVC V C F 31U3U3FG 1 St...

Page 8: ...ion See section 1 Control cube 2 LEDs for status and operation mode 7 1 3 Capacity adjusting knob 7 1 4 100 key 7 1 5 Signal inputs outputs 5 3 6 Mounting plate 7 Mains connection 8 Operation mode key...

Page 9: ...nlet side bar 2 psi 29 Max viscosity with spring loaded valves2 mPas cP 1000 1000 500 Max viscosity without spring loaded valves2 mPas cP 100 Min internal hose pipe diameter inlet outlet side1 3 mm 19...

Page 10: ...5 mA Min pulse length ms 5 Max pulse frequency Hz 100 Max loop resistance in external circuit 150 Impedance at 4 20 mA analog input 15 Accuracy of analog input full scale value 0 5 Min resolution of a...

Page 11: ...rial stainless steel C 120 The dosing head material Polyvinyl chloride PVC must not be used in CIP applications TM06 7312 4218 C B 283 5 G5 4 A1 D A 140 5 25 194 183 5 4 x 7 4 x 9 187 159 140 29 36 17...

Page 12: ...e pump on the mounting plate 1 Remove the locking screws from their transport position on the mounting plate 2 Place the pump on the mounting plate support clamps and slide it in as far as possible Th...

Page 13: ...teed in conjunction with lines supplied by Grundfos The lines used must comply with the pressure limits as per section 4 1 Technical data Important information on installation Observe suction lift and...

Page 14: ...collecting tray Fig 7 Hydraulic connection Pipe connection type U3U3 For details on connection types see section 3 5 Type key 1 Make sure the system is pressureless 2 Push union nut 2 across pipe 3 3...

Page 15: ...A3 5 3 Electrical connection Mains connection The mains plug is the separator separating the pump from the mains All electrical connections must be carried out by a qualified electrician in accordance...

Page 16: ...rous voltage by means of double or reinforced insulation TM06 7315 3216 2 1 3 4 4 2 3 4 1 2 1 3 2 1 GND GND DDE AR DDE B DDE AR DDE AR DDE AR 1 2 3 4 1 2 3 4 3 4 1 2 1 2 5 3 4 Symbol Function Pin assi...

Page 17: ...knob to 100 and wait until liquid flows out of the deaeration hose continuously and without any bubbles Then set the capacity adjusting knob back to 0 7 Close the deaeration valve The pump is deaerat...

Page 18: ...erating statuses and faults LED on LED flashing empty table cell LED off For some alarms the pump tries to restart periodically Observe section 9 Faults TM06 7320 4316 Pos Description Control variant...

Page 19: ...on mode the pump doses the set dosing volume for each incoming potential free pulse e g from a water meter The pump automatically calculates the optimum stroke frequency for dosing the set volume per...

Page 20: ...ctivating the external stop signal the pump switches to operating state Standby The active operation mode LED flashes green and the red external stop LED is on The contact type can be changed See sect...

Page 21: ...ed as follows 1 Set adjusting knob to 0 2 Connect power supply See section 5 3 Electrical connection 3 Press 100 key and Operation mode key simultaneously and hold them down for at least 5 seconds The...

Page 22: ...sons authorised by Grundfos Observe section 8 5 Repairs Interval Task Daily Check if liquid leaks from the drain opening on the dosing head and if the drain opening is blocked or soiled See fig 13 14...

Page 23: ...aeration screw 1a 1e O ring 1b Valve ball 1c Valve housing 1d Groove for O ring 1f 1h Flat gasket 1g Hose nipple 2 Flange 2a 2d O ring 2b Screws 2c Intermediate ring 3 Diaphragm 4 Valve on outlet side...

Page 24: ...p housing This section refers to fig 13 14 1 DDE 60 10 Place new O rings 2a 2d in the grooves at flange 2 and make sure they are seated correctly Attach flange 2 observing alignment pin 12 2 DDE 120 7...

Page 25: ...f followed by hose nipple 1g and flat gasket 1h onto valve housing 1c 15 Use special tool A to screw in valve housing 1c into double nipple 5a carefully with a torque wrench Torque Nm 2 0 2 16 Make su...

Page 26: ...s on inlet and outlet side 4 7 7 For plastic dosing head Remove screws 6 Remove dosing head 5 together with cover plate 6a 8 For stainless steel dosing head Remove screws 6 together with washers 6b Re...

Page 27: ...ructions If the above requirements are not met Grundfos may refuse to accept delivery of the pump The shipping costs will be charged to the sender Observe section 2 3 Transport The pump housing must o...

Page 28: ...p status Fault Possible cause Possible remedy Standby Motor blocked Alarm Backpressure greater than nominal pressure Reduce backpressure Observe section 4 1 Technical data Incorrectly installed diaphr...

Page 29: ...lled diaphragm Install the diaphragm correctly Damage to gears Hall sensor failure Motor failure Contact your Grundfos service partner Leaky dirty outlet valve Dosing medium flows back from the outlet...

Page 30: ...all O rings are installed correctly Blocked inlet line Clean inlet line install strainer Suction lift too high Reduce suction lift Install priming aid Viscosity too high Use lines with larger diameter...

Page 31: ...in brief We hereby declare that the pump has been cleaned and is completely free from chemical biological and radioactive substances _____________________________________ Date and signature __________...

Page 32: ...GRUNDFOS CROATIA d o o Buzinski prilaz 38 Buzin HR 10010 Zagreb Phone 385 1 6595 400 Telefax 385 1 6595 499 www hr grundfos com GRUNDFOS Sales Czechia and Slovakia s r o apkovsk ho 21 779 00 Olomouc P...

Page 33: ...b 11070 Novi Beograd Phone 381 11 2258 740 Telefax 381 11 2281 769 www rs grundfos com Singapore GRUNDFOS Singapore Pte Ltd 25 Jalan Tukang Singapore 619264 Phone 65 6681 9688 Telefax 65 6681 9689 Slo...

Page 34: ...835 Trademarks displayed in this material including but not limited to Grundfos the Grundfos logo and be think innovate are registered trademarks owned by The Grundfos Group All rights reserved 2019 G...

Reviews: