18
6. Disposal
This product or parts of it must be disposed of in an environmentally sound
way:
1. Use the public or private waste collection service.
2. If this is not possible, contact the nearest Grundfos company or service
workshop.
Max. cable length
Cable size
Max. cable length at 20 °C
[m]
AWG
Diameter
[mm]
Cross-
sectional area
[mm
2
]
Load
resistance
500R
Load
resistance
250R
17
1.15
1.04
8896
16309
18
1.02
0.82
7055
12934
19
0.91
0.65
5595
10257
20
0.81
0.52
4437
8134
21
0.72
0.41
3518
6451
22
0.64
0.33
2790
5116
23
0.57
0.26
2213
4057
24
0.51
0.20
1755
3217
25
0.45
0.16
1392
2551
26
0.40
0.13
1104
2023
Other data
Enclosure class
IP20
Ambient temperature
During operation
–20 °C to +50 °C (–4 °F to +122 °F)
During storage
–20 °C to +70 °C (–4 °F to +158 °F)
During transport
–20 °C to +70 °C (–4 °F to +158 °F)
Caution
SI 010 CNV must not be exposed to direct sunlight during
operation.
Subject to alterations.