English (GB)
7
The RMQ components are shown in fig.
.
Fig. 1
RMQ components
6. Type key
7. Technical data
7.1 Operating conditions
7.2 Dimensions
Fig. 2
Dimensional sketch (dimensions in mm)
TM
04
73
11
1
8
1
0
Pos.
Description
1
Cabinet
2
Pump
3
Operating panel
4
Mains-water hose
5
Outlet hose
6
Inlet hose
7
Float valve
8
Mains-water tank
9
Emergency overflow
10
Overflow
Example
RMQ 3 -45 B -A -W -A BVBP
Type range
Rated flow rate [m
3
/h]
Maximum head [m]
Code for control variant
A: Electronic controls
B: Electric control
Code for version
A: Standard
Code for pipe connection
W: Internal thread
Code for materials
A: Standard
Code for shaft seal
1
7
8
9
10
2
3
4
5
6
Flow, Q
max.
RMQ -35
RMQ -45
4.0 m
3
/h
4.5 m
3
/h
Head, H
max.
RMQ -35
RMQ -45
35 m
45 m
Liquid temperature
5-35 °C
Maximum inlet pressure,
mains-water connection
6 bar
System pressure
Maximum 7.5 bar
Maximum height to highest
point of consumption
15 m
Supply voltage
230 VAC, 50 Hz
Power input during standby
Approx. 2.5 W
Rated power input
RMQ -35
RMQ -45
Approx. 850 W
Approx. 1000 W
Enclosure class
IP42
Ambient temperature
0-45 °C
Mounting location
Indoors
Weight
24 kg
Material, cabinet
EPP foam
Material, pump
Stainless steel/
POM/PPO
Material, mains-water tank
PE
Dimension, mains-water hose 3/4"
Dimension, inlet and outlet
hoses
1"
Dimension, overflow
DN 70
T
M
02
57
68
06
09
400