English (GB) Installation and operating instructions

Original installation and operating instructions.

CONTENTS

Page

1. Symbols used in this document

2. Scope of supply

Grundfos PM Rain unit.

Grundfos PM Rain unit and SB pump.

Grundfos PM Rain unit and JP pump.
Supplied with an automatic air release valve 
fitted in the priming hole and unions.

1.

Symbols used in this document

3

2.

Scope of supply

3

3.

Applications

4

3.1

Liquids

4

3.2

Temperatures

4

3.3

Operating pressure

4

4.

Installation

4

4.1

Connections

4

4.2

Mechanical installation

5

4.3

Location

5

4.4

Pressure settings

6

4.5

Electrical installation

7

4.6

Connecting units with cable and plug 
fitted

7

4.7

Alternative power supply

7

5.

Control panel

7

5.1

DIP switches

8

5.2

Enabling the DIP switch settings

8

6.

Start-up

9

7.

Operation

9

7.1

Operating principle

9

7.2

Start/stop according to water 
consumption

10

7.3

Start/stop with 1 bar (100 kPa) 
differential pressure

10

8.

Functions

10

8.1

Anti-cycling

10

8.2

Dry-running protection

10

9.

Frost protection

11

10.

List of warnings

12

11.

Technical data

12

12.

Fault finding

13

13.

Further product information

14

14.

Disposal

14

Warning

Prior to installation, read these 
installation and operating instructions. 
Installation and operation must comply 
with local regulations and accepted 
codes of good practice.

Warning

The use of this product requires 
experience with and knowledge of the 
product.
Persons with reduced physical, 
sensory or mental capabilities must not 
use this product, unless they are under 
supervision or have been instructed in 
the use of the product by a person 
responsible for their safety.
Children must not use or play with this 
product.

Warning

If these safety instructions are not 
observed, it may result in personal 
injury.

Warning

If these instructions are not observed, 
it may lead to electric shock with 
consequent risk of serious personal 
injury or death.

Caution

If these safety instructions are not 
observed, it may result in malfunction 
or damage to the equipment.

Note

Notes or instructions that make the job 
easier and ensure safe operation.

Summary of Contents for PM Rain

Page 1: ...GRUNDFOS INSTRUCTIONS PM Rain Installation and operating instructions...

Page 2: ...proximation of the laws of the EC member states Low Voltage Directive 2006 95 EC Standards used EN 60730 1 2000 and EN 60730 2 6 2008 EMC Directive 2004 108 EC Standards used EN 60730 1 2000 and EN 60...

Page 3: ...Functions 10 8 1 Anti cycling 10 8 2 Dry running protection 10 9 Frost protection 11 10 List of warnings 12 11 Technical data 12 12 Fault finding 13 13 Further product information 14 14 Disposal 14 W...

Page 4: ...hout solid particles or fibres that may attack the unit mechanically or chemically 3 2 Temperatures 3 2 1 Liquid temperature 0 to 60 C 3 2 2 Ambient temperature 0 to 55 C 3 3 Operating pressure Max 10...

Page 5: ...e unit so that the height between the unit and the highest tapping point does not exceed the values in the table below Default setting See section 5 1 DIP switches Note Use a suitable thread seal tape...

Page 6: ...rther adjustment is necessary repeat from point 2 When the pressure reducing valve has been adjusted correctly adjust the start pressure accordingly See section 5 1 DIP switches 10 Refit the PM Rain c...

Page 7: ...l installation make sure that the power supply cannot be accidentally switched on The unit must be connected to an external mains switch with a minimum contact gap of 3 mm in all poles As a precaution...

Page 8: ...witch 2 ON Start pressure 2 5 0 5 1 4 bar Start pressure 250 50 100 400 kPa See section 7 2 1 Starting and stopping conditions All set to OFF pstart 2 5 bar pstart 250 kPa 5 STOP START 1 BAR Start sto...

Page 9: ...at a pressure above 2 5 bar 250 kPa the mains water back up will remain inactive See fig 7 If rainwater is no longer available the PM Rain will stop the pump when dry running occurs When the system p...

Page 10: ...atically reset To enable the function set DIP switch 6 to ON See section 5 1 DIP switches 8 1 Anti cycling To detect inadvertent starts and stops of the pump in case of a failure in the installation t...

Page 11: ...not been primed within 3 minutes of operation the dry running warning will reappear The auto reset function will attempt to restart the pump after 24 hours This will be repeated for five days and if r...

Page 12: ...art stop sequences within a short period Each pump start is delayed a few seconds to protect the installation The start delay is active until normal operation has been re established Note The protecti...

Page 13: ...ump is blocked c The pump is defective Repair or replace the pump d The PM Rain is defective Repair or replace the PM Rain 3 The pump does not start when water is consumed Pump on is off a Too big dif...

Page 14: ...ction 8 1 Anti cycling b Cycling There is a minor leakage in the system Note For system without pressure tank Check the system for leaks See section 8 1 Anti cycling c Cycling The pressure tank has no...

Page 15: ...ndix 1 Fig 8 Wiring diagrams Fig 9 Dimensions TM04 9528 4510 TM04 1953 1508 IN M 3 L1 L3 N L1 L2 PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2 1 IN M 1 L1 L1 N PE N U V 1x230 V 50 60 Hz PE 6 OUT 5 4 3 2...

Page 16: ...16...

Page 17: ...17...

Page 18: ...18...

Page 19: ...Peguam U1 25 Glenmarie Industrial Park 40150 Shah Alam Selangor Phone 60 3 5569 2922 Telefax 60 3 5569 2866 New Zealand GRUNDFOS Pumps NZ Ltd 17 Beatrice Tinsley Crescent North Harbour Industrial Est...

Page 20: ...ahead makes it possible Innovation is the essence The name Grundfos the Grundfos logo and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A S or Grundfos A S Denma...

Reviews: