2.4 Other connections

The connection terminals of external potential-free contacts for 
start/stop and digital function, external setpoint signal, sensor sig-
nal, GENIbus and relay signal are shown in fig. 4.

Note:

 If no external on/off switch is connected, short-circuit termi-

nals 2 and 3 using a short wire.

Note:

 As a precaution, the wires to be connected to the following 

connection groups must be separated from each other by rein-
forced insulation in their entire lengths: 

1.

Inputs

 (external start/stop, digital function, setpoint and sen-

sor signals, terminals 1-8, and bus connection, terminals 
A, Y, B). 

All inputs (group 1) are internally separated from the mains-
conducting parts by reinforced insulation and galvanically 
separated from other circuits.
All control terminals are supplied by protective extra-low volt-
age (PELV), thus ensuring protection against electric shock. 

2.

Output

 (relay signal, terminals NC, NO, C). 

The output (group 2) is galvanically separated from other cir-
cuits. A maximum supply voltage of 250 V or protective extra-
low voltage can be connected to the output as desired.

A galvanically safe separation must fulfil the requirements for re-
inforced insulation including creepage distances and clearances 
specified in EN 60 335.

Fig. 4

Connection terminals

2.5 Signal cables 

Use screened cables having a cross-sectional area of min. 
0.5 mm² and max. 1.5 mm² for external on/off switch, digital in-
put, setpoint and sensor signals. 

The screens of the cables must be connected to frame at both 
ends with good frame connection. They must be as close as 
possible to the terminals, fig. 5. 

Fig. 5

Stripped cable with screen and wire connection

Screws for frame connections must always be tightened 
whether a cable is fitted or not. 

The wires in the pump terminal box must be as short as possi-
ble. 

2.6 Bus connection cable

2.6.1 New installations

For the bus connection a screened 3-core cable having a cross-
sectional area of min. 0.5 mm² and max. 1.5 mm² must be used. 

If the pump is connected to a unit with a cable clamp which is 
identical to the one on the pump, the screen must be con-
nected to this cable clamp. 

If the unit has no cable clamp as shown in fig. 6, the screen is 
left unconnected at this end.

Fig. 6

Connection with screened 3-core cable

2.6.2 Replacing an existing pump

If a screened 2-core cable is used in the existing installation, it 
must be connected as shown in fig. 7. 

Fig. 7

Connection with screened 2-core cable

If a screened 3-core cable is used in the existing installation, 
follow the instructions in section 

2.6.1 New installations.

TM

02 19

52 260

Gro

up 2

G

rou
p 1

8: +24 V
7: Sensor input
6: GND (frame)
5: +5 V
4: Setpoint input
3: GND (frame)
2: Start/stop
1: Digital input

A: RS-485A

Y: Screen

B: RS-485B

Signal relay

NC

NO

C

TM

02

 13

25 

09

01

T

M

02

 88

41

 09

0

4

TM

02

 88

42

 09

04

A

Y

B

A

Y

B

1

2

3

1

2

3

Pump

A

Y

B

A

Y

B

1

2

1

2

Pump

Summary of Contents for NBE

Page 1: ...TPE D NBE NKE 11 22 kW GRUNDFOS INSTRUCTIONS Installation and operating instructions...

Page 2: ...quais esta declara o se refere est o em conformidade com as Directivas Comunit rias com aproxima o das leis dos estados membros da CE para M quinas 98 37 CE Norma usada EN ISO 12100 Compatibilidades...

Page 3: ...73 23 EEZ 95 Primenjeni standardi EN 60 335 1 i EN 60 335 2 51 Prohl en o shod My firma Grundfos prohla ujeme na svou odpov dnost e v robky TPE D NBE a NKE na n se toto prohl en vztahuje jsou v soula...

Page 4: ...4...

Page 5: ...iones de instalaci n y funcionamiento 60 Instru es de instala o e funcionamento 73 86 Installatie en bedieningsinstructies 99 Monterings och driftsinstruktion 112 Asennus ja k ytt ohjeet 125 Montering...

Page 6: ...structions should be stud ied carefully Furthermore the enclosed installa tion and operating instructions for the standard pump should be studied carefully The installation and operation should also b...

Page 7: ...ting DC and smooth DC fault currents occur For these pumps an earth leakage circuit breaker type B must be used This circuit breaker must be marked with the following symbols Note When an earth leakag...

Page 8: ...cross sectional area of min 0 5 mm and max 1 5 mm for external on off switch digital in put setpoint and sensor signals The screens of the cables must be connected to frame at both ends with good fram...

Page 9: ...ion The setpoint value corresponds to 100 of the maximum pump performance see data sheet for the pump Other pump settings are marked with bold faced type under each individual display in sections 5 1...

Page 10: ...s continuously to change to the min curve of the pump bottom light field flashes When the bottom light field is on must be pressed for 3 seconds before the light field starts flash ing To return to un...

Page 11: ...R100 offers additional possibilities of setting and status dis plays for the pump The displays are divided into four parallel menus fig 16 0 GENERAL see operating instructions for the R100 1 OPERATION...

Page 12: ...signal range Setpoint signal outside signal range Other fault A fault indication can be reset in this display if the cause of the fault has disappeared 5 1 4 Alarm log If faults have been indicated t...

Page 13: ...time Ti is set within the range from 0 1 to 3600 s If 3600 s is selected the controller will function as a P controller Furthermore it is possible to set the controller to inverse control if the setpo...

Page 14: ...input of the pump terminal 1 fig 4 can be set to dif ferent functions Select one of the following functions Min min curve Max max curve The selected function is activated by closing the contact betwe...

Page 15: ...ternal setpoint Hlower 20 0 x 80 0 16 m In uncontrolled operation mode the setpoint can be set exter nally within the range from the min curve to the setpoint set on the pump or by means of the R100 f...

Page 16: ...p erate according to the max curve the pump control panel and the R100 can only set the pump to stop Example If via the digital input the pump has been forced to op erate according to the max curve th...

Page 17: ...an installation incorporating E pumps is not al lowed as the built in electronics may be damaged TM00 7600 0304 Green Red Indicator lights Signal relay activated during Description Fault red Opera ti...

Page 18: ...5 mm Maximum cable length 500 m 12 4 Other technical data EMC electromagnetic compatibility EN 61 800 3 Immunity to electromagnetic disturbance second environment industrial areas Contact Grundfos for...

Page 19: ...u City Shizuoka pref 431 21 Phone 81 53 428 4760 Telefax 81 53 484 1014 Korea GRUNDFOS Pumps Korea Ltd 6th Floor Aju Building 679 5 Yeoksam dong Kangnam ku 135 916 Seoul Korea Phone 82 2 5317 600 Tele...

Page 20: ...www grundfos com Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96480952 1104 139 Repl 96480952 1102...

Reviews: