10.2 The motor-protective circuit breaker trips immediately when the power supply is
switched on
Cause
Remedy
A fuse is blown or the motor-protective circuit breaker
has tripped.
Replace the fuse or reset the motor-protective circuit
breaker.
The contacts in the motor-protective circuit breaker
are faulty.
Replace the motor-protective circuit breaker contacts.
The cable connection is loose or faulty.
Fasten or replace the cable connection.
The motor winding is defective.
Replace the motor.
The pump is mechanically blocked.
Remove the mechanical blocking of the pump.
The overload setting for the motor-protective circuit
breaker is too low.
Set the motor-protective circuit breaker correctly.
10.3 The motor-protective circuit breaker trips occasionally
Cause
Remedy
The overload setting for the motor-protective circuit
breaker is too low.
Set the motor-protective circuit breaker correctly.
The voltage is low at peak times.
Ensure a constant power supply.
10.4 The motor-protective circuit breaker has not tripped, but the motor does not run
Cause
Remedy
Power supply failure.
Connect the power supply.
One or more fuses are blown.
Replace the fuses.
The thermal protection has tripped.
Reactivate the thermal protection.
The main contacts in the motor-protective circuit
breaker are not making contact, or the coil is faulty.
Replace the contacts or the magnetic coil.
The control circuit is defective.
Repair the control circuit.
18
English (GB)
Summary of Contents for MTR 1
Page 1: ...MTR 50 60 Hz IEC Installation and operating instructions GRUNDFOS INSTRUCTIONS...
Page 2: ......
Page 27: ...7 5 22 kW MG MGE TM068598 7 5 45 kW MG MGE TM068599 4 4 1 4 1 1 4 1 1 4 1 5 27 CN...
Page 32: ...7 2 1 2 1 1 TM016428 3 TM075491 4 5 6 7 8 MG MGE 32 CN...
Page 34: ...9 9 1 MG MGE 8 1 34 CN...
Page 35: ...10 8 3 1 10 1 10 2 10 3 35 CN...
Page 36: ...10 4 36 CN...
Page 37: ...10 5 10 6 10 7 IEC 60034 17 dU dt 6 2 37 CN...
Page 48: ...6 CUE OFF EN 60204 1 5 3 2 3 6 1 90 4 270 o 180 o 90 o 0 o TM004257 1 2 3 4 5 48 KO...
Page 50: ...2 1 1 TM016428 3 TM075491 4 5 6 7 8 MG MGE 50 KO...
Page 52: ...9 9 1 MG MGE 8 1 52 KO...
Page 53: ...10 8 3 1 10 1 10 2 53 KO...
Page 54: ...10 3 10 4 54 KO...
Page 55: ...10 5 10 6 10 7 IEC 60034 17 dU dt 6 2 55 KO...
Page 70: ...10 8 3 1 10 1 10 2 10 3 70 TW...
Page 71: ...10 4 71 TW...