English (GB)
11
7. Technical data
Maximum ambient temperature
35 or 55 °C. See the nameplate.
Liquid temperature
Domestic use: 0-35 °C or 0-60 °C. See the
nameplate.
Other use: 0-40 °C.
Maximum operating pressure
6 bar, 600 kPa.
Maximum flow rate
Maximum head
Maximum inlet pressure
Maximum suction lift
JPA, JPC: 8 m, including a pressure loss, at a liquid
temperature of 20 °C.
JPD: 27 m.
Pump type
[m
3
/h]
JPA 3-42 / JPA 3-42 PT-H
3
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
4
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
4
JPA 5-61 / JPA 5-61 PT-V
5
JPA 8-62 / JPA 8-62 PT-V
8
JPA 12-41
12
JPA 12-51
12
JPC 3-42 / JPC 3-42 PT
3
JPC 4-47 / JPC 4-47 PT
4
JPC 4-54 / JPC 4-54 PT
4
JPC 5-48
5
JPD 4-47 PT
4
JPD 4-54 PT
4
JPD 5-61 PT
5
JPD 8-62 PT
8
Pump type
[m]
JPA 3-42 / JPA 3-42 PT-H
42
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
47
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
54
JPA 5-61 / JPA 5-61 PT-V
61
JPA 8-62 / JPA 8-62 PT-V
62
JPA 12-41
41
JPA 12-51
51
JPC 3-42 / JPC 3-42 PT
42
JPC 4-47 / JPC 4-47 PT
47
JPC 4-54 / JPC 4-54 PT
54
JPC 5-48
48
JPD 4-47 PT
47
JPD 4-54 PT
54
JPD 5-61 PT
61
JPD 8-62 PT
62
Pump type
[bar]
[MPa]
JPA 3-42 / JPA 3-42 PT-H
3.8
0.38
JPA 4-47 / JPA 4-47 PT-H /
JPA 4-47 PT-V
3.3
0.33
JPA 4-54 / JPA 4-54 PT-H /
JPA 4-54 PT-V
2.6
0.26
JPA 5-61 / JPA 5-61 PT-V
1.9
0.19
JPA 8-62 / JPA 8-62 PT-V
1.8
0.18
JPA 12-41
3.9
0.39
JPA 12-51
2.9
0.29
JPC 3-42 / JPC 3-42 PT
1.8
0.18
JPC 4-47 / JPC 4-47 PT
1.3
0.13
JPC 4-54 / JPC 4-54 PT
0.6
0.06
JPC 5-48
1.2
0.12
JPD 4-47 PT
1.3
0.13
JPD 4-54 PT
0.6
0.06
JPD 5-61 PT
1.9
0.19
JPD 8-62 PT
1.8
0.18
Summary of Contents for JPA 12-41