There are 3 connection stubs with 1/2" threads on
the front panel of the product.
1. Connect the stub labeled "SUPPLY IN" to the
flow pipe.
2. Connect the stub labeled "RETURN IN" to the
return pipe.
3. Connect the stub labeled "RETURN OUT" to the
return pipe.
Fig. 1
Connecting to pit measure point
3.3 Throttle valve
The throttle valve is by default set to 3, and the cover
is loosely attached.
3.4 Antenna
Connect the supplied antenna to the antenna
connector labeled "GSM".
For optimal antenna conditions, we recommend
drilling diagonally from the road into the well and
sending the receiving part of the antenna into the
hole. It is important that there is sufficient air around
the receiving part of the antenna, and we therefore
recommend placing the antenna in a conduit. Refill
the hole in the road afterwards. See fig
Fig. 2
Positioning the antenna
T
M
0
7
4
10
7 0
319
The product is designed for installation in a
humid environment. We recommend
placing the product in the well in order to
minimise the risk of flooding the product in
connection to, for example, heavy rain.
Place the product on, for example, a shelf
or on top of the exposed main lines.
Flow pipe
Return pipe
CAUTION
Falling hazard
Minor or moderate personal injury
- Place the antenna cable away from the
walking path.
- Ensure that the antenna cable is fixed
with cabel ties.
CAUTION
Exposure to RF radiation
Minor or moderate personal injury
- After installing the antenna, stay at
minimum 20 cm away from it.
TM
07
41
08
031
9
Antenna