English (GB)
6
3. Technical data
1)
Liquids with viscosity similar to water
2)
Applies to the inside of the suction installation. The container must be unpressurised!
3)
Also for suction lances, the indicated cable length is measured starting from the valve body
4)
When installed, without packaging
Data
Foot valve and
suction lance (PE)
Foot valve and
suction lance
(PVDF)
Foot valve
(stainless steel)
Mechanical data
Max. flow rate
1)
[l/h]
60
[gph]
15.85
Max. pressure
2)
[bar]
2
[psi]
29
Max. liquid temperature
[°C]
45
60
80
Min. liquid temperature
[°C]
0
0
-10
Max. ambient temperature
[°C]
45
Min. ambient temperature
[°C]
0
0
-10
Max. storage temperature
[°C]
45
Min. storage temperature
[°C]
0
0
-10
Electrical data
(for versions with
two-step level
indication)
Length of included signal cable
3)
[m]
5
5
-
Type of included signal cable
LIY2Y
LIY2Y
-
Max. voltage of reed switches
[V]
48
48
-
Max. current of reed switches
[A]
0.5
0.5
-
Max. load of reed switches
[VA]
10
10
-
Weight
4)
Suction lance
[kg]
0.28 - 0.4
0.43 - 0.62
-
Foot valve without level
indication
[kg]
0.11
0.13
0.18
Foot valve with level indication
[kg]
0.26
0.28
-