5.4 Disassembly of pumps

Complete disassembly instructions are outlined below. Proceed 
only as far as required to perform the maintenance work needed.

1. Turn of power.

2. Drain System. Flush, if necessary.

3. Remove motor hold down bolts.

5.4.1 Disassembly of liquid end

1. Remove casing bolts that attaches the volute to the bracket. 

Set volute aside.

For EB 20503-2:

1. Inspect impeller for anti-reversing set screws. 

2.Impeller and set screws will need to be evenly heated to 

approximately 350 ºF to loosen locktite.

3. To hold rotating element steady, remove the drip canopy and 

fan cover exposing the opposite end of the shaft. 

4. Use the proper hand tool required to hold the shaft steady for 

impeller removal. 

5. Once proper heat has been applied and the shaft can be held 

secure, remove impeller. 

6. Remove capscrews that fasten the bracket to the motor.

7. Place bracket on flat surface and press out seal seat. 

For EB 20501-5: 

1. Loosen and remove the impeller capscrew along with impeller 

washer.

2. Use approximate size gear puller aligned behind impeller 

vanes to remove impeller from shaft. 

3. Remove impeller key. 

4. Remove capscrews that fasten the bracket to the motor. 

5. Place bracket on flat surface and press out seal seat. 

6. If shaft sleeves requires replacement, it must be evenly 

heated to approximately 350 ºF to loosen locktite. 

7. Twist sleeve off shaft. 

5.5 Reassembly of pumps

1. All parts should be cleaned before reassembly.

2. Refer to parts list to identify required replacement items 

Specify pump serial or catalog number when ordering parts.

3. Reassembly is the reverse of disassembly.

4. Observe the following when reassembling the liquid end:

– All mechanical seal components must be in good condition 

or leakage may result. Replacement of complete seal 
assembly is recommended.

– New shaft sleeves are installed by bonding to shaft with 

hydraulic setting locktite.

5.6 Ordering parts

Grundfos Pumps has over 90 years of experience in the design, 
manufacture, and application of centrifugal pumps and pumping 
systems. Grundfos's commitment to state-of-the-art pump design 
and quality manufacturing assures maximum user benefits with 
optimum equipment life at lower cost. Grundfos’s commitment to 
their customers continues through an extensive service 
organization. Highly trained technicians can assist customers 
with initial startup, troubleshooting, repair, and system analysis. 

To ensure that the proper replacement parts are ordered for your 
particular pump model, see the Parts kit section 5.7.

5.7 Parts kit

Warning

Depending on the product being pumped, the 
pump should be washed down before any work is 
done on it.

Warning

Observe extreme caution when venting and/or 
draining hazardous liquids. Wear protective 
clothing in the presence of caustic, corrosive, 
volatile, flammable, or hot liquids. DO NOT 
breathe toxic vapors. DO NOT allow sparking, 
flames, or hot surfaces in vicinity of the 
equipment.

Caution

Do not insert screwdriver between impeller vanes 
to prevent rotation. It may be necessary to use a 
strap wrench around the impeller or shaft to 
prevent rotation.

Pump Model

Seal Kit

Impeller/Wear ring Kit

EB 20503-2

91909684

98351890

EB 20501-5

91910839

98351903

Summary of Contents for EB 20501-5

Page 1: ...GRUNDFOS INSTRUCTIONS End gun booster Installation and operating instructions...

Page 2: ...2...

Page 3: ...ILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES OR EXPENSES ARISING FROM INSTALLATION USE OR ANY OTHER CAUSES THERE ARE NO EXPRESS OR IMPLIED WARRANTIES INCLUDING MERCHANTABILITY...

Page 4: ...f installations are threaded straight onto the nipple where the suction must be the same size no decrease in pipe size at suction allowed Discharge pipe size will be the same at the pump or may be one...

Page 5: ...on performance curve 8 Check and record voltage amperage per phase and kilowatts if a wattmeter is available 4 5 Voltage regulation The motor will operate satisfactorily under the following conditions...

Page 6: ...ion normal or light loading clean air 100 F maximum ambient temperature Severe conditions Continuous 24 hour operation shock loading or vibration poor ventilation 100 150 F ambient temperature Extreme...

Page 7: ...ent items Specify pump serial or catalog number when ordering parts 3 Reassembly is the reverse of disassembly 4 Observe the following when reassembling the liquid end All mechanical seal components m...

Page 8: ...8...

Page 9: ...9...

Page 10: ...10...

Page 11: ...Grundfos companies U S A Grundfos CBS Inc 902 Koomey Road Brookshire TX 77423 USA Phone 281 994 2700 Toll Free 1 800 955 5847 Fax 1 800 945 4777...