1
TM040362
Alignment with shims
Pos.
Description
1
Shims
3.1.7 Vibration dampening
Elimination of noise and vibrations is best achieved
by means of a concrete foundation, vibration dampers
and expansion joints.
If you use vibration dampers, install them under the
foundation. For pumps with motor size below or equal
to 30 kW, you can use vibration dampers as shown in
fig. Pump on vibration dampers.
For pumps with motor size equal to 37 kW or above,
you can use a Sylomer
®
1
2
1
TM067999
Pump on vibration dampers
Pos.
Description
1
Expansion joints
2
Vibration dampers
1
2
1
TM068000
Pump on Sylomer
®
plate
Pos.
Description
1
Expansion joints
2
Sylomer
®
plate
3.1.8 Outdoor installation
When the pump is installed outdoors, we recommend
that you provide the motor with a rain cover. We also
recommend that you open one of the drain holes in
the motor flange.
15
English (GB)
Summary of Contents for CRN 125-11