Figure B
Maximum inlet pressure and maximum flow rate
50 Hz
Pump type
Maximum inlet
pressure
Maximum
flow rate
[bar]
[MPa]
[m
3
/h]
CR, CRN 95
120
95-1-1 → 95-1
4
0.4
95-2-2 → 95-3-2
10
1
95-3 → 95-6
15
1.5
95-7 → 95-12
20
2
CR, CRN 125
160
125-1 → 125-2-1
10
1
125-2 → 125-4
15
1.5
125-5 → 125-12
20
2
CR, CRN 155
200
155-1-1 → 155-1
10
1
155-2-2 → 155-3
15
1.5
155-4-1 → 155-11-1
20
2
CR, CRN 185
240
185-1-1
10
1
185-1 → 185-2
15
1.5
185-3-3 → 185-8
20
2
CR, CRN 215
280
215-1-1 → 215-2-2
15
1.5
215-2-1 → 215-7-2
20
2
CR, CRN 255
330
255-1-1 → 255-1
15
1.5
255-2-2 → 255-6-2
20
2
60 Hz
Pump type
Maximum inlet
pressure
Maximum
flow rate
[bar]
[MPa]
[m
3
/h]
CR, CRN 95
150
95-1-1 → 95-2-2
10
1
95-2-1 → 95-4-2
15
1.5
95-4 → 95-7
20
2
CR, CRN 125
190
125-1-1
10
1
125-1 → 125-3-2
15
1.5
125-3-1 → 125-9-3
20
2
CR, CRN 155
230
155-1-1
10
1
155-1 → 155-2-1
15
1.5
155-2 → 155-8-3
20
2
CR, CRN 185
280
185-1-1 → 185-1
15
1.5
185-2-1 → 185-6-4
20
2
CR, CRN 215
336
215-1-1
15
1.5
215-1 → 215-4-1
20
2
CR, CRN 255
400
255-1-1 → 255-4-3
20
2
881
Appendix A
Summary of Contents for CRN 125-11