Illustration
Information
1
TM069134
Arrows on the pump base plate show the direction of flow of liquid
through the pump.
2
TM069156
These dimensions are stated in Figure C:
•
port-to-port lengths
•
dimensions of the base plate
•
pipe connections
•
diameter and position of anchor bolts.
3
TM070783
The pump can be installed vertically and horizontally. If you wish to install
a pump horizontally, it must be ordered with support brackets fitted from
factory and a foot-mounted motor.
3a
TM057705
Additional support. As the centre of gravity of the pump is relatively high,
we recommend that pumps installed on ships, in areas with risk of earth
quake or in systems which can be moved, are equipped with an addition-
al support bracket. You can fit the bracket from the motor stool to the
bulkhead of the ship, a rigid wall in a building or to a rigid part.
4
TM0201
16
To minimise possible noise from the pump, we recommend that you fit ex-
pansion joints on either side of the pump.
Build a foundation and carry out mechanical installation as described in
section Foundation.
Fit isolating valves on either side of the pump to avoid draining the sys-
tem if the pump needs to be removed for cleaning, repair or replacement.
Always protect the pump against backflow by means of a non-return
valve.
5
TM0201
14
Install the pipes so that air pockets do not occur.
6
TM0201
15
Fit a vacuum valve close to the pump if the installation has one of these
characteristics:
•
The outlet pipe slopes downwards away from the pump.
•
There is a risk of siphon effect.
•
Protection against backflow of unclean liquids is needed.
Related information
13
English (GB)
Summary of Contents for CRN 125-11