4. EZ Boost Quick Guide
4.1 . EZ Boost Quick Selection Guide
Example:
1. The maximum demand is 15 GPM (3.4 m3/h).
2. The pressure required is 70 PSI system pressure
at the taps in the building.
3. The normal minimum inlet pressure (e.g. city
pressure) is 20 PSI.
4. The additional boost required is 50 PSI at 15 GPM
(3.4 m
3
/h).
5. Select a 15 BMQE 05A-110.
4.2. EZ Boost System Diagram
The EZ Boost Constant Pressure System should consist of:
Pos.
1. EZ Boost BMQE pump
2. EZ Boost controller
3. Diaphragm tank
(recommended size 2 U.S. gallons (8 liter)/130 psi)
2
3
4
1
5
6
6